Nuclear, Thermal, and Shielding Design of Test Cell in A-FNS

https://repo.qst.go.jp/records/2001957
https://repo.qst.go.jp/records/2001957
4643c4d6-c360-45f2-94eb-6a6894384a93
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-12-18
タイトル
タイトル Nuclear, Thermal, and Shielding Design of Test Cell in A-FNS
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Honda Shogo

× Honda Shogo

Honda Shogo

Search repository
Saerom Kwon

× Saerom Kwon

Saerom Kwon

Search repository
Kenjo Shunsuke

× Kenjo Shunsuke

Kenjo Shunsuke

Search repository
Oyaizu Makoto

× Oyaizu Makoto

Oyaizu Makoto

Search repository
Ochiai Kentaro

× Ochiai Kentaro

Ochiai Kentaro

Search repository
Sato Satoshi

× Sato Satoshi

Sato Satoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Significant quantities of neutrons and gamma rays deduce the nuclear heating on the shielding walls of the test cell (TC) in the A-FNS. This study presents nuclear and thermal analyses of the shielding wall in the A-FNS to evaluate its radiation-shielding effectiveness and cooling capacity. Previous designs incorporated cooling water pipes embedded in the concrete shielding wall for thermal management. However, we determined that this approach failed to maintain concrete temperatures within specified limits due to the low thermal conductivity of concrete and the challenge of ensuring adequate contact between the concrete and piping. We developed a new shielding wall design that eliminates the need for cooling pipes inside the concrete. This updated design integrates an 85 cm of stainless steel 316 L (SS316L) structure containing 20 % cooling water positioned in front of the concrete, which maintains concrete temperatures within acceptable limits. In addition, nuclear assessments of this revised shielding wall structure were conducted to verify its radiation shielding capacity. Results indicate that the effective dose criteria are met at thicknesses of 255 cm for heavy concrete and 335 cm for ordinary concrete when the 85 cm of combing structure of SS316L/water (20 % water) is included.
書誌情報 Fusion Engineering and Design

巻 223, 号 115549, 発行日 2026-02
出版者
出版者 ELSEVIER
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2025.115549
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:29:59.191737
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3