ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Spectroscopic analysis and internal dose assessment in lung counting for reactor-grade Pu compounds

https://repo.qst.go.jp/records/2001918
https://repo.qst.go.jp/records/2001918
2952c355-a488-486e-9fee-5cd885bfedb3
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-11-04
タイトル
タイトル Spectroscopic analysis and internal dose assessment in lung counting for reactor-grade Pu compounds
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Naito Masayuki

× Naito Masayuki

Naito Masayuki

Search repository
Mihei Yuma

× Mihei Yuma

Mihei Yuma

Search repository
Yajima Kazuaki

× Yajima Kazuaki

Yajima Kazuaki

Search repository
Tamakuma Yuki

× Tamakuma Yuki

Tamakuma Yuki

Search repository
Kim Eunjoo

× Kim Eunjoo

Kim Eunjoo

Search repository
Tani Kotaro

× Tani Kotaro

Tani Kotaro

Search repository
Kowatari Munehiko

× Kowatari Munehiko

Kowatari Munehiko

Search repository
Kurihara Osamu

× Kurihara Osamu

Kurihara Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Internal contamination with plutonium (Pu) isotopes represents one critical exposure scenario in nuclear fuel cycle facilities. Lungcounting is commonly employed as the initial individual monitoring method following inhalation of Pu. Due to the low detection sensitivity for characteristic X-rays emitted by Pu isotopes, the γ-ray emitted by coexisting 241Am is typically used as a surrogate for measurement. However, it is essential to establish clear procedures applicable in cases of severe internal exposure. In this study, key challenges associated with lung counting and dose assessment were examined, focusing on an inhalation event of reactor-grade Pu compounds containing 238Pu to 242Pu. These challenges included: complex spectral peak analysis; increased minimum detectable activity for Pu isotopes due to interference from 241Am; and evaluation of the minimum assessable dose considering Pu isotopic composition. Based on these considerations, procedures from lung counting to internal dose assessment were refined to support emergency response.
書誌情報 Radiation Protection Dosimetry

巻 201, 号 18, p. 1210-1219, 発行日 2025-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0144-8420
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncaf114
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:28:11.446220
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3