Thoron exhalation rate measurement – findings from a large worldwide intercomparison study

https://repo.qst.go.jp/records/2001816
https://repo.qst.go.jp/records/2001816
f2bf823e-5f01-4ab3-85c8-28378bbfc2dc
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-06-18
タイトル
タイトル Thoron exhalation rate measurement – findings from a large worldwide intercomparison study
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 G. de With

× G. de With

G. de With

Search repository
G. Venoso

× G. Venoso

G. Venoso

Search repository
A. Maiorana

× A. Maiorana

A. Maiorana

Search repository
C. Di Carlo

× C. Di Carlo

C. Di Carlo

Search repository
O. Meisenberg

× O. Meisenberg

O. Meisenberg

Search repository
Q. Guo

× Q. Guo

Q. Guo

Search repository
Miroslaw Janik

× Miroslaw Janik

Miroslaw Janik

Search repository
E.D. Nugraha

× E.D. Nugraha

E.D. Nugraha

Search repository
O.M. Bobbo

× O.M. Bobbo

O.M. Bobbo

Search repository
C. Kranrod

× C. Kranrod

C. Kranrod

Search repository
M. Hosoda

× M. Hosoda

M. Hosoda

Search repository
S. Tokonami

× S. Tokonami

S. Tokonami

Search repository
B.K. Sahoo

× B.K. Sahoo

B.K. Sahoo

Search repository
S.D. Kanse

× S.D. Kanse

S.D. Kanse

Search repository
J. Tschiersch

× J. Tschiersch

J. Tschiersch

Search repository
抄録
内容記述タイプ Abstract
内容記述 A global intercomparison study was conducted to measure the thoron (220Rn) exhalation rate from two building materials, with participation from five European laboratories and three Asian laboratories. The test samples—phosphogypsum and unfired clay—were circulated among the laboratories using a sequential proficiency testing scheme. The assigned values and their uncertainties were determined through recommended robustness analysis. For comparison, the classical method, which uses the arithmetic mean of all participants' results, was also applied. Individual measurement results were evaluated for bias, precision, and proficiency in accordance with ISO 13528:2022.The assigned exhalation rates were (0.39 ± 0.15) Bq m−2 s−1 for phosphogypsum and (0.53 ± 0.15) Bq m−2 s−1 for unfired clay. Z-scores were below 3 for seven of the nine methods used. Bias (Rb) and precision (P) parameters were within 50 %, except in one case. Laboratories provided details on Type A and Type B uncertainties, revealing that detector calibration uncertainty was the dominant factor in most cases.These findings underscore the need for more robust calibration methods to improve the accuracy of thoron measurements. The development of a harmonised standard would greatly enhance the consistency of thoron exhalation rate measurements. Such a standard should provide guidance on detector calibration, as well as key factors such as climate conditions during sample preparation and testing, procedures for determining exhalation rates and their uncertainties, and considerations for material aging and spatial variations.
書誌情報 Radiation Measurements

巻 187, p. 107471, 発行日 2025-10
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radmeas.2025.107471
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:23:26.269618
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3