JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection

https://repo.qst.go.jp/records/2001813
https://repo.qst.go.jp/records/2001813
ddc0f14c-c126-45a5-b7e7-0454f880c863
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-12-23
タイトル
タイトル JT-60SA Central Solenoid Conductor Hotspot Risk Analysis for High Voltage Protection
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Zani Louis

× Zani Louis

Zani Louis

Search repository
Théo FRANCONNET

× Théo FRANCONNET

Théo FRANCONNET

Search repository
Luca NOVELLO

× Luca NOVELLO

Luca NOVELLO

Search repository
Quentin LE COZ

× Quentin LE COZ

Quentin LE COZ

Search repository
Benoit LACROIX

× Benoit LACROIX

Benoit LACROIX

Search repository
MARÍA MERCEDES GUZMÁN CASADO

× MARÍA MERCEDES GUZMÁN CASADO

MARÍA MERCEDES GUZMÁN CASADO

Search repository
Sonoda Shogo

× Sonoda Shogo

Sonoda Shogo

Search repository
Murakami Haruyuki

× Murakami Haruyuki

Murakami Haruyuki

Search repository
Hamada Kazuya

× Hamada Kazuya

Hamada Kazuya

Search repository
抄録
内容記述タイプ Abstract
内容記述 The upgrade to JT-60SA tokamak (R=3m, a=1.2m) was conducted within a Europe-Japan collaboration agreement featuring the implementation of superconducting magnets. In 2021, an arcing issue on EF1 coil led to an overall magnets insulation reinforcement against high voltage. The Central Solenoid (CS), less accessible for repair, deserves specific attention versus its voltage exposure. Risk mitigation was initiated by decreasing the power supply voltage during plasma scenario current transients. But to further minimize risk, it was decided to address the case of fast discharge events, less frequent but likely to be the risk-driver case as inducing the highest voltage. Its value during discharge being proportional to the external dump resistance, it is envisaged to decrease this resistance of 30%. The consequence is a slower current decrease after a quench event, inducing a higher Joule energy absorbed by conductor, therefore a higher temperature rise in the conductor, increasing the risk of thermo-mechanical degradation due to hotspot occurrence.It is therefore needed to conduct a risk analysis associated to this mitigation action and the present paper exposes the different steps passed in this aim. The first step includes the development and cross-check of two thermo-hydraulic models of CS winding pack that independently evaluate the maximum temperature of CS conductor components using THEA and GANDALF tools. Then, several standard reference cases of quench events and associated CS discharges are investigated for different quench detection conditions. The overall results are presented and discussed regarding the influence of detection settings. Further to the reference cases in question, several parametric studies are conducted considering variants on parameters bearing uncertainties in their definition. This encompasses e.g. the quench location, the quench zone length, the current variation pattern or the copper RRR value. This step aims to establish a more accurate estimation of the impact derived from those intrinsic uncertainties on quench event features. In addition some potential investigations on the use of possible margins are shown. For this risk evaluation, a particular emphasis is given to the methodology followed to define hotspot risk criteria, and to the rationale and references supporting the establishment of those methodologic elements. After application of those rules to the above mentioned modelling results, the risk evaluation outcomes are discussed with the aim of issuing a consolidated assessment on the absolute risk faced by the CS magnet in case of quench event. Finally, recommendations are made regarding the possibility to validate and implement the decision to decrease the CS magnet dump resistance by the JT-60SA project team in order to better protect the CS from applying high voltage.
書誌情報 IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY

巻 36, 号 3, p. 1-5, 発行日 2026-05
出版者
出版者 IEEE
DOI
識別子タイプ DOI
関連識別子 10.1109/TASC.2025.3632240
戻る
0
views
See details
Views

Versions

Ver.1 2026-01-06 05:23:13.904968
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3