| アイテムタイプ |
学術雑誌論文 / Journal Article(1) |
| 公開日 |
2025-03-17 |
| タイトル |
|
|
タイトル |
Dose assessment for radioactive products distributed on liquid Li loops of fusion neutron sources |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
| 著者 |
Kenjo Shunsuke
Oyaizu Makoto
Saerom Kwon
Ochiai Kentaro
Sato Satoshi
|
| 抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Radiation dose rates around liquid Li loops in International Fusion Materials Irradiation Facility (IFMIF)-like fusion neutron sources, such as A-FNS, increase because of the radionuclides produced by high-energy deuterons and neutrons. This study assesses radiation dose rates around the pipe, heat exchanger (HX), and electromagnetic pump (EMP) of a liquid Li loop using the Monte Carlo code MCNP6.2 and the photon data library mcplib84 to advance the development of maintenance strategies. The radiation sources include not only major nuclides (tritium and Be-7) reported in previous studies but also other radionuclides that have not been well investigated thus far. The calculation results suggest that hands-on maintenance of Li pipes can be performed after the Li drain. However, accesses HX and EMP are limited because of nuclides such as Y-88, which are produced from impurities in liquid Li, even when Be-7 is trapped in Cold Trap. |
| 書誌情報 |
Fusion Engineering and Design
巻 214,
号 114901,
発行日 2025-03
|
| 出版者 |
|
|
出版者 |
ELSEVIER |
| DOI |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.1016/j.fusengdes.2025.114901 |