Coloration-dependent correction for heavy ion measurements in an Al2O3:C,Mg-based fluorescent nuclear track detector
https://repo.qst.go.jp/records/2001480
https://repo.qst.go.jp/records/2001480db913168-3d82-4f30-aace-1b78a3147aa7
| アイテムタイプ | 学術雑誌論文 / Journal Article(1) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2025-02-07 | |||||||||||
| タイトル | ||||||||||||
| タイトル | Coloration-dependent correction for heavy ion measurements in an Al2O3:C,Mg-based fluorescent nuclear track detector | |||||||||||
| 言語 | en | |||||||||||
| 言語 | ||||||||||||
| 言語 | eng | |||||||||||
| 資源タイプ | ||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
| 資源タイプ | journal article | |||||||||||
| 著者 |
Hu Jun
× Hu Jun
× Kusumoto Tamon
× Kodaira Satoshi
|
|||||||||||
| 抄録 | ||||||||||||
| 内容記述タイプ | Abstract | |||||||||||
| 内容記述 | To reduce or eliminate fluctuations in fluorescence intensity due to optical absorption and spherical aberration of a focused laser beam, and variations in color center concentrations between individual Al2O3:C,Mg-based fluorescent nuclear track detectors (FNTDs), we adopted the intensities of F22+ (2 Mg) and F2+ (2 Mg) color centers corresponding to green and near-infrared (NIR) colorations, respectively. These intensities were used to develop coloration-dependent correction methods to improve accuracy of the FNTD-based heavy ion measurements. The FNTDs were irradiated with He, C, Ne, and Fe ions to prepare mono-energetic and multi-energetic specimens and then the performance of the correction methods was evaluated. Both the green and NIR coloration-dependent correction methods eliminated fluctuations in fluorescence intensity with depth, reducing the coefficient of variation (CV) by 36.6% and 35.9%, respectively. The green coloration-dependent correction method also reduced fluctuations of fluorescence intensity due to color centers by decreasing CVw by 45.3%. The NIR coloration-dependent correction method was ineffective for correcting fluctuations due to color centers compared to the green coloration-dependent correction. The fluorescence intensities of He, C, and Fe tracks corrected by green and NIR colorations in the multi-energetic specimen coincided with those of mono-energetic specimens. Hence, these methods provide reliable and standardized approaches for heavy ion measurements and have the potential to be applied in determining the LET of heavy ions. | |||||||||||
| 書誌情報 |
Radiation Measurements 巻 181, p. 107384, 発行日 2025-02 |
|||||||||||
| 出版者 | ||||||||||||
| 出版者 | Elsevier | |||||||||||
| ISSN | ||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||
| 収録物識別子 | 1879-0925 | |||||||||||
| DOI | ||||||||||||
| 識別子タイプ | DOI | |||||||||||
| 関連識別子 | 10.1016/j.radmeas.2025.107384 | |||||||||||