Imaging of therapeutic carbon-ion beams in a human-head phantom measuring prompt X-rays
https://repo.qst.go.jp/records/2001465
https://repo.qst.go.jp/records/200146533ae603f-5c3f-41c6-9515-33ddd18a5ac9
| アイテムタイプ | 学術雑誌論文 / Journal Article(1) | |||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2025-01-28 | |||||||||||||||||||||||||||||
| タイトル | ||||||||||||||||||||||||||||||
| タイトル | Imaging of therapeutic carbon-ion beams in a human-head phantom measuring prompt X-rays | |||||||||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||||||||||||
| 著者 |
Yamaguchi Mitsutaka
× Yamaguchi Mitsutaka
× Yamamoto Seiichi (Waseda Univ.)
× Kitano Maki (Nagoya Univ.)
× Yabe Takuya
× Akagi Takashi (Hyogo Ion Beam Medical Center)
× Kataoka Jun (Waseda Univ.)
× Kamada Kei (Tohoku Univ.)
× Yoshikawa Akira (Tohoku Univ.)
× Nagao Yuuto
× Tsuda Michiko
× Watabe Hiroshi
× Kawachi Naoki
|
|||||||||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||||||||
| 内容記述 | The purpose of this study is to evaluate the feasibility of monitoring therapeutic carbon-ion beams by measuring prompt X-rays in the clinical application of head treatment. Specifically, we investigated the ability to identify 2-cm differences in beam arrival depth in a head phantom using secondary electron bremsstrahlung. First, a Monte Carlo simulation was conducted. A head phantom was positioned at the center of the simulation space, surrounded by 24 X-ray cameras, and three carbon-ion beams were irradiated. Next, an experimental study was performed using the same beam configuration, with X-ray cameras acquiring images from parietal and temporal-head directions. Simulation results indicated that beam images could be acquired over a wide range of ±135 degrees from the parietal direction, distinguishing 1.8-cm depth differences. Experimentally obtained images were consistent with simulations. These findings suggest that prompt X-ray imaging is a promising tool for monitoring therapeutic carbon-ion beams. | |||||||||||||||||||||||||||||