Verification of linear energy transfer optimized carbon-ion radiotherapy

https://repo.qst.go.jp/records/2001445
https://repo.qst.go.jp/records/2001445
37f7afdf-32a0-4499-87f9-bef758d735ef
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-01-17
タイトル
タイトル Verification of linear energy transfer optimized carbon-ion radiotherapy
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Mizuno Hideyuki

× Mizuno Hideyuki

Mizuno Hideyuki

Search repository
Nakaji Taku

× Nakaji Taku

Nakaji Taku

Search repository
Sung-Hyun Lee

× Sung-Hyun Lee

Sung-Hyun Lee

Search repository
Sakata Dousatsu

× Sakata Dousatsu

Sakata Dousatsu

Search repository
Aoki Katsumi

× Aoki Katsumi

Aoki Katsumi

Search repository
Mizushima Kota

× Mizushima Kota

Mizushima Kota

Search repository
Thuy Linh Tran

× Thuy Linh Tran

Thuy Linh Tran

Search repository
Anatoly Rosenfeld

× Anatoly Rosenfeld

Anatoly Rosenfeld

Search repository
Inaniwa Taku

× Inaniwa Taku

Inaniwa Taku

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective Linear energy transfer (LET) verification was conducted using a silicon-on-insulator (SOI) microdosimeter during the commissioning of LET-optimized carbon-ion radiotherapy. This advanced treatment technique is expected to improve local control rates, especially in hypoxic tumors. Approach An SOI microdosimeter with a cylindrical sensitive volume of 30 μm diameter and 5 μm thickness was used. Simple cubic plans and patient plans using the carbon-ion beams were created by treatment planning system, and the calculated LETd values were compared with the measured LETd values obtained by the SOI microdosimeter. Main results Reasonable agreement between the measured and calculated LETd was seen in the plateau region of depth LETd profile, whereas the measured LETd were below the calculated LETd in the peak region, specifically where LETd exceeds 75 keV/μm. The discrepancy in the peak region may arise from the uncertainties in the calibration process of the SOI microdosimeter. Excluding the peak region, the average ratio and standard deviation between measured and calculated LETd values were 0.996 and 7%, respectively. Significance This verification results in the initiation of clinical trials for LET-optimized carbon-ion radiotherapy at QST Hospital, National Institutes for Quantum Science and Technology.
書誌情報 Physics in Medicine and Biology

巻 69, 号 23, p. NT01, 発行日 2024-11
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1361-6560
PubMed番号
識別子タイプ PMID
関連識別子 39509821
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ad8fec
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:53:03.996760