Simple and convenient preconcentration procedure for the isotopic analysis of uranium in seawater

https://repo.qst.go.jp/records/2001395
https://repo.qst.go.jp/records/2001395
1ba93d8f-936f-47ab-850a-f8e37862c227
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-12-10
タイトル
タイトル Simple and convenient preconcentration procedure for the isotopic analysis of uranium in seawater
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Abe Minami

× Abe Minami

Abe Minami

Search repository
Seko Noriaki

× Seko Noriaki

Seko Noriaki

Search repository
Hoshina Hiroyuki

× Hoshina Hiroyuki

Hoshina Hiroyuki

Search repository
S. Wada

× S. Wada

S. Wada

Search repository
S. Yamasaki

× S. Yamasaki

S. Yamasaki

Search repository
K. Sueki

× K. Sueki

K. Sueki

Search repository
抄録
内容記述タイプ Abstract
内容記述 The demandfor monitoring anthropogenic U isotopes, 236U and 233U, in seawater will continue to increase due to radioecological issues and the need for tools for environmental dynamics research. In response to this growing demand, herein, a novel and simple method was developed for the collection of U isotopes in seawater, both in the laboratory and field, using a fabric-like amidoxime adsorbent. The results from the adsorption studies showed that the optimum conditions for processing seawater in a glass beaker were as follows: seawater pH 4, amidoxime adsorbent 0.20 mmol per 500 g seawater and an adsorption time of 9 hours. Alternatively, when using a closed polyethylene container in experiments on-board a ship and using the same ratio of adsorbent to seawater as in the beaker experiment in the laboratory, the optimum conditions were as follows: seawater pH 8 and an adsorption time of 24 hours. Under the above-mentioned conditions, more than 95% of the U underwent adsorption in both the beaker and the polyethylene container experiments. In the case of analyte desorption, more than 80% of U in seawater was recovered using 2?3 mol dm?3 HCl or HNO3 as the eluent. Thus, it was concluded that the amidoxime adsorbent can serve as a simple and effective pre-concentration method for the ultra-trace monitoring of U isotopes in seawater.
書誌情報 Analytical Methods

発行日 2024-12
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:51:27.324314
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3