Application of the spectral determination method to unified gamma-, beta- and X-ray spectra

https://repo.qst.go.jp/records/2001320
https://repo.qst.go.jp/records/2001320
951f3d18-6b10-4a26-b7a9-fba72ca833f5
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-01-21
タイトル
タイトル Application of the spectral determination method to unified gamma-, beta- and X-ray spectra
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Masumi Oshima

× Masumi Oshima

Masumi Oshima

Search repository
Jun Goto

× Jun Goto

Jun Goto

Search repository
Hayakawa Takehito

× Hayakawa Takehito

Hayakawa Takehito

Search repository
Masato Asai

× Masato Asai

Masato Asai

Search repository
Hirofumi Shinohara

× Hirofumi Shinohara

Hirofumi Shinohara

Search repository
Katsuyuki Suzuki

× Katsuyuki Suzuki

Katsuyuki Suzuki

Search repository
Haifeng Shen

× Haifeng Shen

Haifeng Shen

Search repository
抄録
内容記述タイプ Abstract
内容記述 So far we have developed the innovative radioactivity quantification technique of spectral determination method (SDM) based on the first principle that a γ-ray spectrum obtained for a sample is a linear superposition of individual spectra of the radioactive nuclides included in the sample. We have applied this method to spectra measured with Ge, NaI detectors and liquid scintillation counter (LSC) and demonstrated that the determination uncertainty of the SDM was better than those of previous peak analysis methods for the spectra obtained from a sample including 8 or 9 radionuclides.
In the present study we extended the SDM to apply to a unified spectrum composed of LSC and Ge detector, and the number of nuclides has been increased to 40. The new SDM code was named as SDM-LG. We selected 40 radionuclides from possible radionuclides included in nuclear debris and radioactive wastes in the environment which were produced by the nuclear accident in Fukushima in March. 2011. We carried out LSC and Ge measurements for 17 and 7 nuclides, respectively. The rest of the standard spectra among the 40 nuclides have been derived by simulation calculations utilizing the Geant 4.10.3 Monte Carlo simulation tool kit. The derived LSC and Ge spectra for each nuclide were unified to a single spectrum and the 40 sets of the composed spectra were completed as a unified data base.
We studied the determination accuracy of the SDM-LG analysis by examining a composed spectrum made of 40 radionuclides with equal intensities (Each has a radioactivity fraction of 2.5%.). The SDM result shows that the relative determination uncertainties of 35 nuclides are below 20%. It is also indicated that by removing 3 interfering nuclides the determination accuracy of the other 37 nuclides could be improved.
書誌情報 Journal of Nuclear Science and Technology

発行日 2025-01
出版者
出版者 Taylor & Francis
DOI
識別子タイプ DOI
関連識別子 10.1080/00223131.2024.2439921
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:49:03.141942