ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

In Silico Study of Simultaneous Integrated Boost Carbon-Ion Radiotherapy for Locally Advanced Pancreatic Cancer

https://repo.qst.go.jp/records/2001303
https://repo.qst.go.jp/records/2001303
57614b2c-4d7d-4724-ad1d-49d3b7db7ece
Item type 学術雑誌論文 / Journal Article(1)
公開日 2024-09-02
タイトル
タイトル In Silico Study of Simultaneous Integrated Boost Carbon-Ion Radiotherapy for Locally Advanced Pancreatic Cancer
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Nakaji Taku

× Nakaji Taku

Nakaji Taku

Search repository
Shinoto Makoto

× Shinoto Makoto

Shinoto Makoto

Search repository
Yamada Shigeru

× Yamada Shigeru

Yamada Shigeru

Search repository
Inaniwa Taku

× Inaniwa Taku

Inaniwa Taku

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background/Aim: Carbon-ion radiotherapy (CiRT) has been used for the treatment of locally advanced pancreatic cancer (LAPC) with uniform dose plan. The aim of the present study is to investigate the effectiveness of a simultaneous integrated boost (SIB) technique with scanned CiRT against LAPC. Materials and Methods: Data of 21 patients with LAPC were used to compare two treatment planning approaches: a conventional uniform dose approach and a SIB approach. A relative biological effectiveness (RBE)-weighted dose (DRBE) of 55.2 Gy (RBE) in 12 fractions was prescribed to the planning target volume (PTV) in the conventional approach. In the SIB approach, DRBE of 67.2 Gy (RBE) and 43.2 Gy (RBE) in 12 fractions were prescribed to a high-risk PTV (HR-PTV) and low-risk PTV (LR-PTV), respectively. The DRBE and dose averaged linear energy transfer (LETd) of targets and gastrointestinal tracts as organs at risk (OARs) were evaluated. Results: The HR-PTV D90% and LR-PTV D90% were 64.4±0.6 and 42.5±0.1 Gy (RBE) in SIB approach compared to the PTV D90% of 54.1±0.4 Gy (RBE) in the conventional approach. All SIB plans achieved the D2cc lower than 46 Gy (RBE) and V30 lower than 4 cm3 within OARs. The SIB approach increased the minimum LETd within the GTV to 44 keV/μm or higher for 20 out of 21 patients as compared to 16 out of 21 patients in the conventional approach. Conclusion: The SIB approach effectively increased the RBE-weighted dose and LETd within the HR-PTV and GTV by accumulating the high-LET stopping carbon-ions into the HR-PTV in addition to the decreased RBE-weighted dose to OARs.
書誌情報 Anticancer Research

巻 44, 号 9, p. 3821-3828, 発行日 2024-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 1791-7530
PubMed番号
識別子タイプ PMID
関連識別子 39197905
DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.21873/anticanres.17208
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:48:28.762267
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3