  1. 原著論文

Effect of Pebble bed Electrical Resistivity on Electromagnetic Force in WCCB TBM

https://repo.qst.go.jp/records/2001293
https://repo.qst.go.jp/records/2001293
f6a8e10e-beb8-4798-8aa4-a4f11bf76086
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-08-20
タイトル
タイトル Effect of Pebble bed Electrical Resistivity on Electromagnetic Force in WCCB TBM
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Wenhai Guan

× Wenhai Guan

Wenhai Guan

Search repository
Hattori Kentaro

× Hattori Kentaro

Hattori Kentaro

Search repository
Hirose Takanori

× Hirose Takanori

Hirose Takanori

Search repository
Kawamura Yoshinori

× Kawamura Yoshinori

Kawamura Yoshinori

Search repository
抄録
内容記述タイプ Abstract
内容記述 Functional materials (multiplier and breeder) formed a pebble bed are considered in many breeding blanket (BB) concepts in both ITER test blanket module (TBM) program and DEMO fusion reactor. In a magnetic confinement fusion reactor, it is crucial to thoroughly assess the impact of pebble bed electrical resistivity on electromagnetic (EM) forces during a plasma disruption. This is essential for maintaining the structural integrity and normal operations of the reactor in an intense and gradient magnetic field environment. However, there is a lack of information and rare study related to pebble bed electrical resistivity investigations affecting EM force performance in a magnetic confinement fusion reactor, which might impact the existing design achievements. The study proposes and conducts parametric pebble bed electrical resistivity analyses to investigate Lorentz force performance in the current structural design of water-cooled ceramic breeder (WCCB) under ITER major plasma disruption event load. The proposed electrical resistivities (7.2 $\times$ 10 $^{-7}$ $\Omega $ m, 3.0 $\times$ 10 $^{-4}$ $\Omega $ m, and infinity) cover a wide design range. The transient EM numerical analyses compare the performance of WCCB TBM with different electrical resistivities. The results show that the maximum Lorentz force of WCCB TBM is almost 38% higher when the pebble bed electrical resistivity is 3.0 $\times$ 10 $^{-4}$ $\Omega $ m compared to 7.2 $\times$ 10 $^{-7}$ $\Omega $ m. No significant difference in maximum Lorentz force is observed when the pebble bed electrical resistivity is increased to infinity. Further investigations reveal that the higher magnitude of Lorentz force in cases with higher pebble bed electrical resistivity is induced by conduction current flows. As the pebble bed electrical resistivity increases, conduction current moves from the pebble bed to the container and the U-shaped cooling channels fabricated from reduced activation ferritic/martensitic steel named F82H, owing to its lower electrical resistivity. Based on these findings, the application of higher pebble bed electrical resistivity could be recognized as a conservative and robust approach in the preliminary design phase of BB development to avoid adverse impacts on the design achievements.
書誌情報 IEEE TRANSACTIONS ON PLASMA SCIENCE

発行日 2024-08
DOI
識別子タイプ DOI
関連識別子 10.1109/TPS.2024.3441528
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 05:48:09.688847
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3