  1. 原著論文

Development of air-cooled plasma grid system for long-pulse negative ion beam acceleration with ITER-relevant perveance

https://repo.qst.go.jp/records/2001205
https://repo.qst.go.jp/records/2001205
a5fc8665-39fa-4dce-a156-aa3ccd0fb8d7
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-05-23
タイトル
タイトル Development of air-cooled plasma grid system for long-pulse negative ion beam acceleration with ITER-relevant perveance
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kisaki Masashi

× Kisaki Masashi

Kisaki Masashi

Search repository
Tanaka Yasuyuki

× Tanaka Yasuyuki

Tanaka Yasuyuki

Search repository
Suzuki Kazune

× Suzuki Kazune

Suzuki Kazune

Search repository
Hiratsuka Junichi

× Hiratsuka Junichi

Hiratsuka Junichi

Search repository
Murayama Masamichi

× Murayama Masamichi

Murayama Masamichi

Search repository
Ichikawa Masahiro

× Ichikawa Masahiro

Ichikawa Masahiro

Search repository
Tobari Hiroyuki

× Tobari Hiroyuki

Tobari Hiroyuki

Search repository
Kashiwagi Mieko

× Kashiwagi Mieko

Kashiwagi Mieko

Search repository
抄録
内容記述タイプ Abstract
内容記述 Long pulse beam experiment has been carried out with a multi-aperture and five-stage accelerator with the same gap length, the same aperture interval, and the same aperture diameter as ITER accelerator in order to demonstrate ITER-relevant beam of 230 Am-2 and 870 keV. An actively cooled plasma grid (PG) with compressed air has been newly developed to maintain the PG temperature within suitable range for surface production of hydrogen negative ion (H?) and to realize the stable H? production. It is confirmed that the air-cooled PG has a capability to control the PG temperature within target range for 300 s with feedback control of the air flow rate. The stable beam acceleration with ITER relevant perveance has been successfully achieved for 300 s at 275 keV with PG cooling, 100 s at 500 keV, and 10 s at 750 keV without PG cooling.
書誌情報 Journal of Physics: Conference Series

巻 2743, 号 1, p. 012042-1-012042-5, 発行日 2024-05
DOI
識別子タイプ DOI
関連識別子 10.1088/1742-6596/2743/1/012042
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 04:46:49.340623
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3