WEKO3
アイテム
In-vacuum post-compression of optical probe pulse for relativistic plasma diagnostics
https://repo.qst.go.jp/records/2001197
https://repo.qst.go.jp/records/20011977cd63e60-5005-4cd6-bdb7-3ccb6e3991e0
| アイテムタイプ | 学術雑誌論文 / Journal Article(1) | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2024-06-19 | |||||||||||||||||||||||||||||||||||||||||||||
| タイトル | ||||||||||||||||||||||||||||||||||||||||||||||
| タイトル | In-vacuum post-compression of optical probe pulse for relativistic plasma diagnostics | |||||||||||||||||||||||||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||||||||||||||||||||||||||||
| 著者 |
Sebastian Lorenz
× Sebastian Lorenz
× Gabriele Maria Grittani
× Kondo Kotaro
× Kon Akira
× Liu Yung-kun
× Sagisaka Akito
× Ogura Koichi
× Nakanii Nobuhiko
× KAI HUANG
× Andreas Bierwage
× Namba Shinichi
× Ohhiro Hikari
× Pikuz Tatiana
× James Kevin Koga
× Pisin Chen
× Kiriyama Hiromitsu
× Kando Masaki
× Esirkepov Timur
× Sergey Bulanov
× Alexander Pirozhkov
|
|||||||||||||||||||||||||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||||||||||||||||||||||||
| 内容記述 | Ultrafast optical probing is a widely used method of underdense plasma diagnostic. In relativistic plasma, the motion blur limits spatial resolution in the direction of motion. For many high-power lasers the initial pulse duration of 30- 50 fs results in a 10-15 μm motion blur, which can be reduced by probe pulse post-compression. Here we used the Compression after Compressor Approach (CafCA) [Phys.-Usp. 62, 1096 (2019); JINST 17 P07035 (2022)], where spectral broadening is performed in thin optical plates and is followed by reflections from negative-dispersion mirrors. Our initially low-intensity probe beam was down-collimated for a more efficient spectral broadening and higher probe-to-self-emission intensity ratio. The setup is compact, fits in vacuum chamber, and can be implemented within a short experimental time slot. We proved that the compressed pulse kept high quality necessary for plasma probing. |
|||||||||||||||||||||||||||||||||||||||||||||
| 書誌情報 |
High Power Laser Science and Engineering 発行日 2024-06 |
|||||||||||||||||||||||||||||||||||||||||||||
| 出版者 | ||||||||||||||||||||||||||||||||||||||||||||||
| 出版者 | Cambrigde University Press | |||||||||||||||||||||||||||||||||||||||||||||
| DOI | ||||||||||||||||||||||||||||||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||||||||||||||||||||||||||||
| 関連識別子 | 10.1017/hpl.2024.29 | |||||||||||||||||||||||||||||||||||||||||||||