WEKO3
アイテム
Metrology for sub-Rayleigh-length target positioning in ~10^22 W/cm^2 laser-plasma experiments
https://repo.qst.go.jp/records/2001093
https://repo.qst.go.jp/records/20010933847c9fa-51ae-44ae-b508-362c93401210
| Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2024-03-07 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| タイトル | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| タイトル | Metrology for sub-Rayleigh-length target positioning in ~10^22 W/cm^2 laser-plasma experiments | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 著者 |
E. A. Vishnyakov
× E. A. Vishnyakov
× Akito Sagisaka
× Koichi Ogura
× Esirkepov Timur
× Bruno Gonzalez izquierdo
× C. Armstrong
× T. A. Pikuz
× S. A. Pikuz
× W. Yan
× T. M. Jeong
× S. Singh
× P. Hadjisolomou
× O. Finke
× G. Grittani
× M. Nevrkla
× C. Lazzarini
× A. Velyhan
× Takehito Hayakawa
× Yuuji Fukuda
× James Kevin Koga
× Masahiko Ishino
× Kotaro Kondo
× Yasuhiro Miyasaka
× Akira Kon
× Masaharu Nishikino
× Y. V. Nosach
× D. Khikhlukha
× I. P. Tsygvintsev
× D. Kumar
× J. Nejdl
× D. Margarone
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 内容記述 | Tight focusing with very small f-numbers is necessary to achieve the highest at-focus irradiances. However, tight focusing imposes strong demands on precise target positioning in-focus to achieve the highest on-target irradiance. We describe several near-infrared, visible, ultraviolet, soft and hard X-ray diagnostics employed in a ~10^22 W/cm^2 laser-plasma experiment. We used ~10 J total energy femtosecond laser pulses focused into a ~1.3-μm focal spot on 5?20 μm thick stainless-steel targets. We discuss the applicability of these diagnostics to determine the best in-focus target position with ~5 μm accuracy (i. e., around ? of the short Rayleigh length) and show that several diagnostics (especially, 3ω reflection and on-axis hard X-rays) can ensure this accuracy. We demonstrated target positioning within several μm from the focus, ensuring over 80% of the ideal peak laser intensity on-target. Our approach is relatively fast (requires 10-20 laser shots) and does not rely on the coincidence of low-power and high-power focal planes. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 書誌情報 |
High Power Laser Science and Engineering 発行日 2024-03 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 出版者 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 出版者 | Cambrigde University Press | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DOI | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 関連識別子 | https://doi.org/10.1017/hpl.2024.11 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||