ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Production of Auger-electron-emitting 103mRh via a 103Pd/103mRh generator using an anion-exchange resin

https://repo.qst.go.jp/records/2000904
https://repo.qst.go.jp/records/2000904
43b271ee-e987-4cee-a8e7-2b80bb73aaac
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-04-22
タイトル
タイトル Production of Auger-electron-emitting 103mRh via a 103Pd/103mRh generator using an anion-exchange resin
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ohya Tomoyuki

× Ohya Tomoyuki

Ohya Tomoyuki

Search repository
Ichinose Jun

× Ichinose Jun

Ichinose Jun

Search repository
Nagatsu Kotaro

× Nagatsu Kotaro

Nagatsu Kotaro

Search repository
Sugo Yumi

× Sugo Yumi

Sugo Yumi

Search repository
Ishioka Noriko

× Ishioka Noriko

Ishioka Noriko

Search repository
Watabe Hiroshi

× Watabe Hiroshi

Watabe Hiroshi

Search repository
Itoh Masatoshi

× Itoh Masatoshi

Itoh Masatoshi

Search repository
Minegishi Katsuyuki

× Minegishi Katsuyuki

Minegishi Katsuyuki

Search repository
Zhang Ming-Rong

× Zhang Ming-Rong

Zhang Ming-Rong

Search repository
抄録
内容記述タイプ Abstract
内容記述 Rhodium-103m is one of the most attractive Auger electron emitters for internal radiotherapy. The half-life of 103mRh is relatively short (56.114 min). Therefore, it needs to be produced using a generator for clinical use. Most studies of 103Pd/103mRh generators using anion-exchange resins were carried out over 50 years ago. However, these resins are no longer commercially available. In the present study, we tested a 103Pd/103mRh generator using alternative anion-exchange resins (i.e., IRA904, IRA410, SA20A, and SA11AL).
No-carrier-added 103Pd was used to make the generators. The 103mRh product was eluted from the generators using 6 mL of 0.1 M HCl with a flow rate 0.5 mL/min. The generator made from SA11AL showed good performance, with a yield of 39 %, an impurity level of 103Pd in the product of 0.29 %, and an
operation time of 14 min. This makes this generator competitive with previously developed ones.
書誌情報 Radiochimica Acta

巻 112, 号 1, p. 37-43, 発行日 2023-11
出版者
出版者 DE GRUYTER
ISSN
収録物識別子タイプ ISSN
収録物識別子 2193-3405
DOI
識別子タイプ DOI
関連識別子 10.1515/ract-2023-0238
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:04:52.079913
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3