Response of personal dosimeters on various age-specific anthropometric phantoms under external irradiation applied to areas affected by the 2011 Fukushima Daiichi nuclear accident

https://repo.qst.go.jp/records/2000852
https://repo.qst.go.jp/records/2000852
a9db6c17-5ef1-4a32-9d2c-09e532e58021
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-04-11
タイトル
タイトル Response of personal dosimeters on various age-specific anthropometric phantoms under external irradiation applied to areas affected by the 2011 Fukushima Daiichi nuclear accident
言語 ja
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 内藤 雅之

× 内藤 雅之

内藤 雅之

Search repository
玉熊 佑紀

× 玉熊 佑紀

玉熊 佑紀

Search repository
矢島 千秋

× 矢島 千秋

矢島 千秋

Search repository
金 ウンジュ

× 金 ウンジュ

金 ウンジュ

Search repository
小原 哲

× 小原 哲

小原 哲

Search repository
谷 幸太郎

× 谷 幸太郎

谷 幸太郎

Search repository
栗原 治

× 栗原 治

栗原 治

Search repository
抄録
内容記述タイプ Abstract
内容記述 We experimentally obtained the responses of two personal dosimeters (PDs, D-shuttle and Dose-i) attached on five age-specific phantoms under rotational irradiation geometry, which simulated an environment that was radiologically affected by the 2011 Fukushima nuclear disaster using of a 137Cs source. Although the PD responses showed an angular phase shift by the PD position on the phantoms, the angular dependence was small when the contamination was widely distributed. The PD responses decreased as much as ~10% with the increase in the phantoms’ body size. Although there were ~17% variations in the PD/ADE (ambient dose equivalent) ratio depending on the different PDs, this variation was due to the fact that D-shuttle was calibrated with the inclusion of a safety margin. The PD/ADE ratios were similar to the effective dose to ADE ratios for corresponding age-specific phantoms. Our results suggest that these two PDs can provide reasonable estimates for age-dependent effective doses.
書誌情報 Radiation Protection Dosimetry

巻 199, 号 15-16, p. 2030-2034, 発行日 2023-10
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1742-3406
DOI
識別子タイプ DOI
関連識別子 10.1093/RPD/NCAD187
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:03:14.068660
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3