ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

A Method for Locally Irradiate Specific Tissue of Model Organisms using Focused Heavy-Ion Microbeam

https://repo.qst.go.jp/records/2000824
https://repo.qst.go.jp/records/2000824
5dbd9a8a-5e1b-4395-bad4-b6f2c848bad3
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-01-08
タイトル
タイトル A Method for Locally Irradiate Specific Tissue of Model Organisms using Focused Heavy-Ion Microbeam
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tomoo Funayama

× Tomoo Funayama

Tomoo Funayama

Search repository
Michiyo Suzuki

× Michiyo Suzuki

Michiyo Suzuki

Search repository
Nobumasa Miyawaki

× Nobumasa Miyawaki

Nobumasa Miyawaki

Search repository
Hirotsugu Kashiwagi

× Hirotsugu Kashiwagi

Hirotsugu Kashiwagi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The functions of organisms are performed by various tissues composed of different cell types. Localized irradiation with heavy-ion microbeams, which inactivate only a portion of the constituent cells without destroying the physical intercellular connections of the tissue, is a practical approach for elucidating tissue functions. However, conventional collimated microbeams are limited in the shape of the area that can be irradiated. Therefore, using a focused heavy-ion microbeam that generates a highly precise beam spot, we developed a technology to uniformly irradiate specific tissues of an organism with a defined dose, which conventional methods cannot achieve. The performance of the developed paint irradiation technology was evaluated. By irradiating the CR-39 ion track detector, we confirmed that the new method, in which each ion hit position is placed uniformly in the irradiated area, makes it possible to uniformly paint the area at a specified dose. The targeted irradiation of the pharynx and gonads of living Caenorhabditis elegans demonstrated that the irradiated ions were distributed in the same shape as the targeted tissue observed under a microscope. This technology will elucidate biological mechanisms that are difficult to analyze with conventional collimated microbeam irradiation.
書誌情報 Biology

巻 12, 号 12, p. 1524, 発行日 2023-12
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2079-7737
DOI
識別子タイプ DOI
関連識別子 10.3390/biology12121524
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:02:20.886936
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3