  1. 原著論文

A large field-of-view angled panel detector for the development of a plant PET system

https://repo.qst.go.jp/records/2000815
https://repo.qst.go.jp/records/2000815
09322ff0-826f-44c7-83cc-0b557a9ade55
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-01-08
タイトル
タイトル A large field-of-view angled panel detector for the development of a plant PET system
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yamamoto Seiichi (Waseda Univ.)

× Yamamoto Seiichi (Waseda Univ.)

Yamamoto Seiichi (Waseda Univ.)

Search repository
Watabe Hiroshi

× Watabe Hiroshi

Watabe Hiroshi

Search repository
Yamaguchi Mitsutaka

× Yamaguchi Mitsutaka

Yamaguchi Mitsutaka

Search repository
Suzui Nobuo

× Suzui Nobuo

Suzui Nobuo

Search repository
Kawachi Naoki

× Kawachi Naoki

Kawachi Naoki

Search repository
Kataoka Jun (Waseda Univ.)

× Kataoka Jun (Waseda Univ.)

Kataoka Jun (Waseda Univ.)

Search repository
抄録
内容記述タイプ Abstract
内容記述 In plant research, positron emission tomography (PET) is sometimes employed for physiological studies of plants. However, due to the generally high cost of PET systems, their application in plant research centers can be challenging. Furthermore, the configurations of commercial PET systems might not always align well with the requirements of plant research. To address these issues, we have taken the initial steps towards a solution by developing a large field-of-view (LFOV) angled panel detector intended for the development of a plant PET system. This panel detector is composed of two gadolinium orthosilicate (GSO) scintillator blocks, an angled light guide, and four flat panel photomultiplier tubes (FP-PMTs). The GSO pixel size used in the scintillator block measures 2.65 mm (radial) × 2.85 mm (axial) × 15.0 mm, arranged in a configuration of 16 (radial) × 32 (axial) to form a scintillator block with overall dimensions of 44.0 mm (radial) × 94.4 mm (axial) × 15 mm (depth). By implementing an angled light guide, the two scintillator blocks were positioned at a 22.5-degree angle, resulting in the creation of a LFOV angled panel detector. This specific angle allowed for the arrangement of 16 scintillator blocks in a hexadecagonal shape using 8 panel detectors when arranged in a circular configuration. We successfully constructed a panel detector with an approximate FOV of 10 cm × 10 cm and conducted a comprehensive performance evaluation. Upon irradiating the panel detector with 511 keV gamma photons, nearly all 1024 GSO pixels were accurately resolved in the position histogram, displaying minimal distortion, and exhibiting an average peak-to-valley ratio of 5.0. Additionally, the energy resolution achieved was 14% full width at half maximum (FWHM). The resulting LFOV angled panel detector holds considerable promise for the use within a cost-effective, user-friendly as well as high performance plant PET system.
書誌情報 Journal of Instrumentation (JINST)

巻 19, p. T01002, 発行日 2024-01
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1748-0221
DOI
識別子タイプ DOI
関連識別子 10.1088/1748-0221/19/01/T01002
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:02:02.612745
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3