ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Optimized Crystal Surface Treatment for Crosshair Light-Sharing TOF-DOI PET Detector

https://repo.qst.go.jp/records/2000798
https://repo.qst.go.jp/records/2000798
022d3da5-5dd4-4308-936a-756272fe5bbe
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-12-27
タイトル
タイトル Optimized Crystal Surface Treatment for Crosshair Light-Sharing TOF-DOI PET Detector
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yoshida Eiji

× Yoshida Eiji

Yoshida Eiji

Search repository
Hangyu Kang

× Hangyu Kang

Hangyu Kang

Search repository
Obata Fujino

× Obata Fujino

Obata Fujino

Search repository
Yamaya Taiga

× Yamaya Taiga

Yamaya Taiga

Search repository
抄録
内容記述タイプ Abstract
内容記述 The coincidence resolving time (CRT) and depthof-
interaction (DOI) resolution of PET detectors are affected by
the crystal surface treatment and the reflective material, and
it is difficult to achieve a balance between their effects. We
have developed the crosshair light-sharing (CLS) detector as
a high-resolution time-of-flight-DOI detector. The CLS detector
uses a three-layered reflective material in a 2-D crystal array to
form a loop structure within a pair of crystals, allowing DOI
information to be acquired even in the 2-D crystal array. In this
study, we investigated the relationship between the crystal surface
treatment and the performance of the detector. Three types
of LYSO:Ca were used: 1) all crystal surfaces were mechanical
polishing (MP); 2) crystals with the one-sided saw-cut surface
(1S); and 3) crystals with the two-sided saw-cut surfaces (2Ss).
The MP crystals showed the best CRT of 286 ps, but the worst
DOI resolution of 7?8 mm. For the 1S crystals, the CRT was
slightly degraded to 296 ps, but the DOI resolution of about
5 mm was obtained. For the 2S crystals, the CRT was significantly
degraded to 332 ps and the DOI resolution was equivalent
to that of the 1S. The crystal array with the 1S showed the best
balance.
書誌情報 IEEE Transactions on Radiation and Plasma Medical Sciences

巻 7, 号 5, p. 459-464, 発行日 2023-03
出版者
出版者 IEEE
ISSN
収録物識別子タイプ ISSN
収録物識別子 2469-7303
DOI
識別子タイプ DOI
関連識別子 10.1109/TRPMS.2023.3255557
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:01:30.021545
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3