  1. 原著論文

Contrast-enhanced ultrasound imaging for monitoring the efficacy of near-infrared photoimmunotherapy

https://repo.qst.go.jp/records/2000774
https://repo.qst.go.jp/records/2000774
950a1fd8-1715-4d67-a37d-c104f5c4acaa
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-12-20
タイトル
タイトル Contrast-enhanced ultrasound imaging for monitoring the efficacy of near-infrared photoimmunotherapy
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kohei Matsuoka

× Kohei Matsuoka

Kohei Matsuoka

Search repository
Mizuki Yamada

× Mizuki Yamada

Mizuki Yamada

Search repository
Noriaki Fukatsu

× Noriaki Fukatsu

Noriaki Fukatsu

Search repository
Kyoichi Goto

× Kyoichi Goto

Kyoichi Goto

Search repository
Misae Shimizu

× Misae Shimizu

Misae Shimizu

Search repository
Ayako Kato

× Ayako Kato

Ayako Kato

Search repository
Yoshimi Kato

× Yoshimi Kato

Yoshimi Kato

Search repository
Hiroshi Yukawa

× Hiroshi Yukawa

Hiroshi Yukawa

Search repository
Yoshinobu Baba

× Yoshinobu Baba

Yoshinobu Baba

Search repository
Mitsuo Sato

× Mitsuo Sato

Mitsuo Sato

Search repository
Kazuhide Sato

× Kazuhide Sato

Kazuhide Sato

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background
Near-infrared photoimmunotherapy (NIR-PIT) is a promising cancer therapy combining NIR-light irradiation with an antibody and IR700DX, a light-sensitive substance, to destroy tumours. However, homogeneous irradiation is difficult because the light varies depending on the distance and tissue environment. Therefore, markers that indicate sufficient irradiation are necessary. Nanoparticles sized 10?200 nm show enhanced permeation and retention within tumours, which is further enhanced via NIR-PIT (super enhanced permeability and retention, SUPR). We aimed to monitor the effectiveness of NIR-PIT by measuring SUPR.

Methods
A xenograft mouse tumour model was established by inoculating human cancer cells in both buttocks of Balb/C-nu/nu mice, and NIR-PIT was performed on only one side. To evaluate SUPR, fluorescent signal examination was performed using QD800-fluorescent nanoparticles and NIR-fluorescent poly (d,l-lactide-co-glycolic acid) (NIR-PLGA) microparticles. Harmonic signals were evaluated using micro-bubbles of the contrast agent Sonazoid and contrast-enhanced ultrasound (CEUS) imaging. The correlation between SUPR immediately after treatment and NIR-PIT effectiveness on the day after treatment was evaluated.

Findings
QD800 fluorescent signals persisted only in the treated tumours, and the intensity of remaining signals showed high positive correlation with the therapeutic effect. NIR-PLGA fluorescent signals and Sonazoid-derived harmonic signals remained for a longer time in the treated tumours than in the controls, and the kE value of the two-compartment model correlated with NIR-PIT effectiveness.

Interpretation
SUPR measurement using Sonazoid and CEUS imaging could be easily adapted for clinical use as a therapeutic image-based biomarker for monitoring and confirming of NIR-PIT efficacy.

Funding
This research was supported by ARIM JAPAN of MEXT, the Program for Developing Next-generation Researchers (Japan Science and Technology Agency), KAKEN (18K15923, 21K07217) (JSPS), CREST (JPMJCR19H2, JST), and FOREST-Souhatsu (JST). Mochida Memorial Foundation for Medical and Pharmaceutical Research; Takeda Science Foundation; The Japan Health Foundation; and Princess Takamatsu Cancer Research Fund.

Funders only provided financial support and had no role in the study design, data collection, data analysis, interpretation, and writing of the report.
書誌情報 eBioMedicine

巻 95, p. 104737, 発行日 2023-08
出版者
出版者 Elsevier BV
ISSN
収録物識別子タイプ ISSN
収録物識別子 2352-3964
DOI
識別子タイプ DOI
関連識別子 10.1016/j.ebiom.2023.104737
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 03:00:43.966417
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3