| アイテムタイプ |
学術雑誌論文 / Journal Article(1) |
| 公開日 |
2024-09-06 |
| タイトル |
|
|
タイトル |
Feasibility study of laser-driven neutron sources for pharmaceutical applications |
|
言語 |
en |
| 言語 |
|
|
言語 |
eng |
| 資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
| 著者 |
Takato Mori
Akifumi Yogo
Yasunobu Arikawa
Takehito Hayakawa
Seyed R. Mirfayzi
Zechen Lan
Tianyun Wei
Yuki Abe
Mitsuo Nakai
Kunioki Mima
Hiroaki Nishimura
Shinsuke Fujioka
Ryosuke Kodama
|
| 抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
We predict the production yield of a medical radioisotope 67Cu using 67Zn(n, p)67Cu and 68Zn(n, pn)67Cu reactions with fast neutrons provided from laser-driven neutron sources (LNDSs). The neutrons were generated by the p+9Be and d+9Be reactions with high energy ions accelerated by laser-plasma interaction. We evaluated the yield to be (3.3x0.5)x10^5 atoms for 67Cu, corresponding to a radioactivity of 1.0+-0.2 Bq, for a Zn foil sample with a single laser shot. Using a simulation with this result, we estimated 67Cu production with a high-frequency laser. The result suggests that it is possible to generate 67Cu with a radioactivity of 270 MBq using a future laser system with a frequency of 10 Hz and 10000-s radiation in a hospital. |
| 書誌情報 |
High Power Laser Science and Engineering
巻 11,
p. e20,
発行日 2023-01
|
| 出版者 |
|
|
出版者 |
Cambrigde University Press |
| ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
2052-3289 |
| DOI |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
10.1017/hpl.2023.4 |