ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Stopping-power ratio of body tissues with updated effective energies and elemental I values for treatment planning of proton therapy and ion beam therapy with helium, carbon, oxygen, and neon ions

https://repo.qst.go.jp/records/2000635
https://repo.qst.go.jp/records/2000635
e1caf7cf-3a9b-4748-9ae8-28b0f3dc325b
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2025-01-17
タイトル
タイトル Stopping-power ratio of body tissues with updated effective energies and elemental I values for treatment planning of proton therapy and ion beam therapy with helium, carbon, oxygen, and neon ions
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Inaniwa Taku

× Inaniwa Taku

Inaniwa Taku

Search repository
Weichert Emely

× Weichert Emely

Weichert Emely

Search repository
Masuda Takamitsu

× Masuda Takamitsu

Masuda Takamitsu

Search repository
Tanaka Sodai

× Tanaka Sodai

Tanaka Sodai

Search repository
Matsufuji Naruhiro

× Matsufuji Naruhiro

Matsufuji Naruhiro

Search repository
Kanematsu Nobuyuki

× Kanematsu Nobuyuki

Kanematsu Nobuyuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 The stopping-power ratio (SPR) of body tissues relative to water depends on the particle energy and mean excitation energy (I value) of the tissues. Effective energies to minimize the range error in proton therapy and ion beam therapy with helium, carbon, oxygen, and neon ions and elemental I values have been updated in recent studies. We investigated the effects of these updates on SPR estimation for computed tomography-based treatment planning. The updates led to an increase of up to 0.5% in the SPRs of soft tissues, whereas they led to a decrease of up to 1.9% in the SPRs of bone tissues compared with the current clinical settings. For 44 proton beams planned for 15 randomly sampled patients, the mean water-equivalent target depth change was ? 0.2 mm with a standard deviation of 0.2 mm. The maximum change was ? 0.6 mm, which we consider to be insignificant in clinical practice.
書誌情報 Radiological Physics and Technology

巻 16, p. 319-324, 発行日 2023-04
出版者
出版者 Springer Nature
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0341
DOI
識別子タイプ DOI
関連識別子 10.1007/s12194-023-00721-6
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:26:08.989900
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3