ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Comprehensive analysis of Japanese nationwide cohort data of particle beam therapy for pulmonary, liver and lymph node oligometastases: particle beam therapy versus high-precision X-ray radiotherapy.

https://repo.qst.go.jp/records/2000588
https://repo.qst.go.jp/records/2000588
902fb0d2-e50c-46cc-9edc-33145bda5f10
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-08-14
タイトル
タイトル Comprehensive analysis of Japanese nationwide cohort data of particle beam therapy for pulmonary, liver and lymph node oligometastases: particle beam therapy versus high-precision X-ray radiotherapy.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Norihiro Aibe

× Norihiro Aibe

Norihiro Aibe

Search repository
Hiroyuki Ogino

× Hiroyuki Ogino

Hiroyuki Ogino

Search repository
Masaru Wakatsuki

× Masaru Wakatsuki

Masaru Wakatsuki

Search repository
Kei Fujikawa

× Kei Fujikawa

Kei Fujikawa

Search repository
Satoshi Teramukai

× Satoshi Teramukai

Satoshi Teramukai

Search repository
Nobuyoshi Fukumitsu

× Nobuyoshi Fukumitsu

Nobuyoshi Fukumitsu

Search repository
Shintaro Shiba

× Shintaro Shiba

Shintaro Shiba

Search repository
Naoyoshi Yamamoto

× Naoyoshi Yamamoto

Naoyoshi Yamamoto

Search repository
Akihiro Nomoto

× Akihiro Nomoto

Akihiro Nomoto

Search repository
Takashi Ono

× Takashi Ono

Takashi Ono

Search repository
Masanosuke Oguri

× Masanosuke Oguri

Masanosuke Oguri

Search repository
Hisashi Yamaguchi

× Hisashi Yamaguchi

Hisashi Yamaguchi

Search repository
Haruko Numajiri

× Haruko Numajiri

Haruko Numajiri

Search repository
Kei Shibuya

× Kei Shibuya

Kei Shibuya

Search repository
Shohei Okazaki

× Shohei Okazaki

Shohei Okazaki

Search repository
Yuhei Miyasaka

× Yuhei Miyasaka

Yuhei Miyasaka

Search repository
Noriyuki Okonogi

× Noriyuki Okonogi

Noriyuki Okonogi

Search repository
Kazutoshi Murata

× Kazutoshi Murata

Kazutoshi Murata

Search repository
Hitoshi Tatebe

× Hitoshi Tatebe

Hitoshi Tatebe

Search repository
Atsushi Motegi

× Atsushi Motegi

Atsushi Motegi

Search repository
Tomoaki Okimoto

× Tomoaki Okimoto

Tomoaki Okimoto

Search repository
Takayuki Yoshino

× Takayuki Yoshino

Takayuki Yoshino

Search repository
Masaki Mandai

× Masaki Mandai

Masaki Mandai

Search repository
Norio Katoh

× Norio Katoh

Norio Katoh

Search repository
Hiroshi Tsuji

× Hiroshi Tsuji

Hiroshi Tsuji

Search repository
Hideyuki Sakurai

× Hideyuki Sakurai

Hideyuki Sakurai

Search repository
抄録
内容記述タイプ Abstract
内容記述 Japanese national oncological experts convened to evaluate the efficacy and safety of particle beam therapy (PT) for pulmonary, liver and lymph node oligometastases (P-OM, L-OM and LN-OM, respectively) and to conduct a statistically comparative analysis of the local control (LC) rate and overall survival (OS) rate of PT versus those of X-ray stereotactic body radiotherapy (X-SBRT) and X-ray intensity-modulated radiotherapy (X-IMRT). They conducted [1] an analysis of the efficacy and safety of metastasis-directed therapy with PT for P-OM, L-OM and LN-OM using a Japanese nationwide multi-institutional cohort study data set; [2] a systematic review of X-ray high-precision radiotherapy (i.e. X-SBRT/X-IMRT) and PT for P-OM, L-OM and LN-OM; and [3] a statistical comparison between LC and OS of the cohort data set in PT and that of the extracted historical data set in X-SBRT/X-IMRT from the preceding systematic review. Safety was evaluated as the incidence of grade???3 adverse events, while statistical comparisons of LC and OS were conducted by estimating the incidence rate ratios (IRR) for local progression and mortality, respectively. This study demonstrated that PT provided durable LC (3-year LC rate: 72.8-83.2%) with acceptable OS (3-year OS rate: 38.5-68.1%) and risk of severe toxicity incidence of 0.8-3.5% in radical metastasis-directed therapy for P-OM, L-OM and LN-OM. Compared to LC with X-SBRT or X-IMRT, LC with PT was potentially superior for P-OM; superior for L-OM; and equivalent for LN-OM. In particular, this study demonstrated that PT may be a new treatment option for L-OM tumors measuring > 5?cm.
書誌情報 Journal of radiation research

巻 64, 号 1, p. i69-i83, 発行日 2023-04
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1349-9157
PubMed番号
識別子タイプ PMID
関連識別子 37053162
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrad004
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:24:38.522335
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3