  1. 原著論文

Modelling activity in support of MITICA High Voltage System protections

https://repo.qst.go.jp/records/2000574
https://repo.qst.go.jp/records/2000574
a7650a78-d0f6-4b92-92fe-e2286b8961d8
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-07-25
タイトル
タイトル Modelling activity in support of MITICA High Voltage System protections
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Mattia Dan

× Mattia Dan

Mattia Dan

Search repository
Marco Boldrin

× Marco Boldrin

Marco Boldrin

Search repository
Vanni Toigo

× Vanni Toigo

Vanni Toigo

Search repository
Francesco Santoro

× Francesco Santoro

Francesco Santoro

Search repository
Loris Zanotto

× Loris Zanotto

Loris Zanotto

Search repository
Tobari Hiroyuki

× Tobari Hiroyuki

Tobari Hiroyuki

Search repository
Ooshita Eiji

× Ooshita Eiji

Ooshita Eiji

Search repository
Hans Decamps

× Hans Decamps

Hans Decamps

Search repository
抄録
内容記述タイプ Abstract
内容記述 MITICA, the full-scale prototype of ITER Heating Neutral Beam (HNBs), has challenging requirements on its power supplies. In particular its unconventional high voltage system is designed to operate at high power and voltage (up to -1 MV dc and about 54 MW), with many interfaces and high voltage insulation technologies co-existing in a single plant. Moreover, the electrical system must manage frequent breakdowns between the accelerator grids during the operation, creating electrical fast transients characterized by extremely high voltage and current peaks. In the conceptual design phase suitable design provisions were conceived to limit the energy in the grids and to limit the overvoltage on specific components in the case of grids-breakdown. The integration tests of the power supplies showed the capability of the system to generate and sustain voltage as high as 700 kV; at higher voltage the voltage withstanding capability was not confirmed as some breakdowns occurred in the plant. Although the location of the breakdowns has not been identified yet, an impact of such breakdowns was highlighted as a couple of the components of the plant suffered a damage. This paper is focused on the analyses performed for the understanding of the fault occurred on the secondary bushing of the 1 MV insulating transformer dedicated to the supply of the Ion Source and Extraction Power Supply system (ISEPS). An extensive activity of modelling and simulation has been developed for explaining the dynamic occurred. The model is based on the stray parameters of the components, which were not easy to be estimated in the design phase, but which turn out to have relevant effects in local fast transient phenomena. After reaching a full understanding of the phenomena, the models have been used to support the conceptual design of an additional protection system for the transformer, for MITICA but also in view of the ITER installation.
書誌情報 Fusion Engineering and Design

巻 190, p. 113517, 発行日 2023-05
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 1873-7196
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2023.113517
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:24:11.698168
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3