ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Spin-Dependent Photocarrier Generation Dynamics in Electrically Detected NV-Based Quantum Sensor

https://repo.qst.go.jp/records/2000548
https://repo.qst.go.jp/records/2000548
eb9ca775-ed70-4a11-8d8b-adc505d0f161
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-07-18
タイトル
タイトル Spin-Dependent Photocarrier Generation Dynamics in Electrically Detected NV-Based Quantum Sensor
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hiroki Morishita

× Hiroki Morishita

Hiroki Morishita

Search repository
Naoya Morioka

× Naoya Morioka

Naoya Morioka

Search repository
Tetsuri Nishikawa

× Tetsuri Nishikawa

Tetsuri Nishikawa

Search repository
Hajime Yao

× Hajime Yao

Hajime Yao

Search repository
Onoda Shinobu

× Onoda Shinobu

Onoda Shinobu

Search repository
Abe Hiroshi

× Abe Hiroshi

Abe Hiroshi

Search repository
Ohshima Takeshi

× Ohshima Takeshi

Ohshima Takeshi

Search repository
Norikazu Mizuochi

× Norikazu Mizuochi

Norikazu Mizuochi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Electrical detection of nitrogen-vacancy (N-V) centers in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors and has the potential to achieve a higher collection efficiency than that of optical techniques. However, the mechanism for the electrical detection of N-V spins is not fully understood. In this study, we observe positive contrast in photocurrent detected magnetic resonance (PDMR). Note that negative PDMR contrast is usually observed. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by N-V centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of N-V centers. Furthermore, we demonstrate ac magnetic field sensing using spin coherence with the PDMR technique. ac magnetic field measurement with the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. Here, we introduce noise suppression using a phase-cycling-based noise-canceling technique. We demonstrate electrically detected ac magnetic field sensing with a sensitivity of 29 nT /Hz-1/2. Finally, we discuss sensitivity enhancement based on the proposed model.
書誌情報 Physcal Review Applied

巻 19, 号 3, p. 034061-1-034061-8, 発行日 2023-03
出版者
出版者 American Physical Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 2331-7019
DOI
識別子タイプ DOI
関連識別子 10.1103/PhysRevApplied.19.034061
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:23:21.056567
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3