ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Evaluation on Nonirradiated Thermo-mechanical response of WCCB TBM following RCC-MRx

https://repo.qst.go.jp/records/2000539
https://repo.qst.go.jp/records/2000539
c09203fe-41c9-45c0-a703-0ca3bc193ac2
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2023-05-15
タイトル
タイトル Evaluation on Nonirradiated Thermo-mechanical response of WCCB TBM following RCC-MRx
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Wenhai Guan

× Wenhai Guan

Wenhai Guan

Search repository
Katagiri Takuya

× Katagiri Takuya

Katagiri Takuya

Search repository
Miyoshi Yuya

× Miyoshi Yuya

Miyoshi Yuya

Search repository
Hirose Takanori

× Hirose Takanori

Hirose Takanori

Search repository
Kawamura Yoshinori

× Kawamura Yoshinori

Kawamura Yoshinori

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since the submodules as the most important structural component in Water-Cooled Ceramic Breeder (WCCB)
Test Blanket Module (TBM) contributes to tritium breeding and extracting, structural integrity assessment is
necessary to keep normal operation and function of WCCB TBM-set. Recently, the nonirradiated material
properties of F82H which is considered as the structural material of submodule has been summarized following
the requirement of RCC-MRx, combined with EU directive, French order, and pressure vessel construction code
(RCC-MRx), structural integrity assessment is investigated under the ITER relevant thermo-mechanical load in
this study. Meanwhile, cooling water conditions of WCCB TBM-set with its operation scenario, relationship, and
detailed values (temperature and pressure) are constituted. Based on the determined structural integrity
assessment procedure from RCC-MRx and numerical analysis results, structural integrity of current design of
submodule in WCCB TBM-set could be validated. According to the current achievements and established
structural integrity assessment procedure, further evaluation on structural integrity combined with electromagnetic
load shall be investigated.
書誌情報 Fusion Engineering and Design

巻 190, p. 113637, 発行日 2023-03
出版者
出版者 ELSEVIER
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2023.113637
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:23:02.528855
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3