| タイトル | Measurements of γ-rays and neutrons in BNCT irradiation field using thermoluminescent phosphor | |||||||||||||||||||||||||||||||||||||||||
| 言語 | en | |||||||||||||||||||||||||||||||||||||||||
| 言語 | ||||||||||||||||||||||||||||||||||||||||||
| 言語 | eng | |||||||||||||||||||||||||||||||||||||||||
| 資源タイプ | ||||||||||||||||||||||||||||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||||||||||||||||||||||||||||
| 資源タイプ | journal article | |||||||||||||||||||||||||||||||||||||||||
| 著者 |
Kiyomitsu Shinsho
× Kiyomitsu Shinsho
× Ryoken Oh
× Masaya Tanaka
× Natsumi Sugioka
× Hiroki Tanaka
× Genichiro Wakabayashi
× Takushi Takata
× Weishan Chang
× Shinnosuke Matsumoto
× Go Okada
× Satoru Sugawara
× Ema Sasaki
× Kenichi Watanabe
× Yusuke Koba
× Kosei Nagasaka
× Sachiko Yoshihashi
× Akira Uritani
× Toru Negishi
|
|||||||||||||||||||||||||||||||||||||||||
| 抄録 | ||||||||||||||||||||||||||||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||||||||||||||||||||||||||||
| 内容記述 | Boron neutron capture therapy (BNCT) is an innovative cancer therapy that selectively destroys only cancer cells by utilizing the reaction between boron agents, which selectively accumulate in cancer cells, and neutron beams. However, the irradiation field in BNCT is a mixture of multiple radiation types, making accurate dose evaluation difficult. For dose evaluation in cancer tissue, which is particularly important, it is essential to discriminate between neutrons and γ-rays mixed in the BNCT irradiation field and to measure them correctly. In this paper, we introduce a new method for selective measurement of neutrons and γ-rays using a thermoluminescent phosphor, which is expected to be a promising method for improving the accuracy of dose evaluations. | |||||||||||||||||||||||||||||||||||||||||
| 書誌情報 |
Japanese Journal of Applied Physics 巻 62, 号 1, p. 010502-1-010502-6, 発行日 2023-03 |
|||||||||||||||||||||||||||||||||||||||||
| 出版者 | ||||||||||||||||||||||||||||||||||||||||||
| 出版者 | IOP Publishing | |||||||||||||||||||||||||||||||||||||||||
| ISSN | ||||||||||||||||||||||||||||||||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||||||||||||||||||||||||||||||||
| 収録物識別子 | 0021-4922 | |||||||||||||||||||||||||||||||||||||||||
| DOI | ||||||||||||||||||||||||||||||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||||||||||||||||||||||||||||
| 関連識別子 | 10.35848/1347-4065/ac971e | |||||||||||||||||||||||||||||||||||||||||