ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Design of optical transmission line of ITER poloidal polarimeter

https://repo.qst.go.jp/records/2000489
https://repo.qst.go.jp/records/2000489
95f05bd1-1016-4e23-a537-39f1a0a97bf0
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-05-23
タイトル
タイトル Design of optical transmission line of ITER poloidal polarimeter
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Imazawa Ryota

× Imazawa Ryota

Imazawa Ryota

Search repository
Takehiro Ono

× Takehiro Ono

Takehiro Ono

Search repository
Hatae Takaki

× Hatae Takaki

Hatae Takaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 ITER Poloidal Polarimeter is laser-aided diagnostics that measures the change of polarization of injected far-infrared laser beam in order to identify plasma current profile. PoPola consists of thirteen measurement chords, and each chord is comprised of a set of optical components. This study shows the design of optics in the ITER vacuum vessel and those in high radiation area outside the vacuum vessel. The design takes into account zero-offset configuration, the minimization of the neutron streaming, remote alignment, accessibility, manufacturability and radiation hardness. The laser power loss due to vignetting loss and absorption is evaluated, and the signal-to-noise ratio at a detector is estimated at 50,000. This study evaluates the acceptable errors of manufacturing and assembly of the optical transmission line on the condition that the demonstrated alignment method using the two steering mirrors outside the vacuum vessel is applied. The evaluation results show that the medium tolerance class of ISO 2768 is basically enough for manufacturing ITER poloidal polarimeter. Only for assembling the in-vessel mirrors to the mirror module, the mirror angles need to be carefully adjusted with accuracy of 0.1° Finally, radiation hardness of a steering mirror is presented. The steering mirror consists of an angle sensor and a piezo actuator. The angle sensors are developed by the authors and free from semiconductor and soft resin. The prototype test results show that angle sensor can measure the mirror angle in the range of ±2.3° with accuracy of 0.37%. As for the piezo actuator, the irradiation test was carried out. The test results show that the piezo actuator is able to operate after the neutron fluence of 3.5 × 1015 n/cm2 and the gamma dose of 0.99 MGy.
書誌情報 Fusion Engineering and Design

巻 192, p. 113607, 発行日 2023-03
出版者
出版者 ELSEVIER
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2023.113607
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:21:23.649330
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3