ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Uncertainties associated with direct thyroid measurements using an NaI(Tl) survey meter: the effect of anatomical differences among individuals

https://repo.qst.go.jp/records/2000404
https://repo.qst.go.jp/records/2000404
fd88d202-e4ef-464b-b603-06ca6d4b173e
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-16
タイトル
タイトル Uncertainties associated with direct thyroid measurements using an NaI(Tl) survey meter: the effect of anatomical differences among individuals
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Narita Masato

× Narita Masato

Narita Masato

Search repository
Tani Kotaro

× Tani Kotaro

Tani Kotaro

Search repository
Kunishima Naoaki

× Kunishima Naoaki

Kunishima Naoaki

Search repository
Kim Eunjoo

× Kim Eunjoo

Kim Eunjoo

Search repository
Kurihara Osamu

× Kurihara Osamu

Kurihara Osamu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Photon detectors utilised for direct thyroid measurements to determine the radioiodine content in the thyroid are normally calibrated using a phantom that mimics the human neck, including the thyroid. However, such measurements are necessarily subject to uncertainty because of the difference between the phantom and the real human subject and also the morphological differences among individuals. In this study, personal voxel phantoms were created from magnetic resonance images of the necks of 24 adult volunteers (15 males and 9 females), and numerical simulations using these phantoms were performed to examine the variation in a conversion factor (131I kBq in the thyroid per μSv h?1) for a conventional NaI(Tl) survey meter among the individuals and also to confirm the suitability of reference Japanese voxel phantoms as a calibration standard for such measurements. As a result, it was found that the conversion factor obtained from the reference Japanese male (female) phantom was 1.29 (1.18) times larger than the average conversion factor for the male (female) subjects, suggesting that the conversion factors of the reference Japanese adult male and female phantoms would generally overestimate the 131I thyroidal contents and that the thyroid volume would be one of the factors influencing the conversion factor. This study also revealed a wide difference in the thyroid volume among individuals, which would be of concern when performing specific dose assessments for heavily exposed persons.
書誌情報 Radiation Protection Dosimetry

巻 199, 号 15-16, p. 1802-1806, 発行日 2023-10
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1742-3406
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncac265
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:18:40.809891
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3