  1. 原著論文

Japanese structure survey of radiation oncology in 2015

https://repo.qst.go.jp/records/2000389
https://repo.qst.go.jp/records/2000389
244feea8-6249-4212-9499-12baf62cf120
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2024-02-28
タイトル
タイトル Japanese structure survey of radiation oncology in 2015
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Numasaki Hodaka

× Numasaki Hodaka

Numasaki Hodaka

Search repository
Nakada Yoshihiro

× Nakada Yoshihiro

Nakada Yoshihiro

Search repository
Ohba Hisateru

× Ohba Hisateru

Ohba Hisateru

Search repository
Okuda Yasuo

× Okuda Yasuo

Okuda Yasuo

Search repository
抄録
内容記述タイプ Abstract
内容記述 This article describes the ongoing structure of radiation oncology in Japan in terms of equipment, personnel, patient
load and geographic distribution to identify and overcome any existing limitations. From May 2016 to August 2018,
the Japanese Society for Radiation Oncology conducted a questionnaire based on the Japanese national structure
survey of radiation oncology in 2015. Data were analyzed based on the institutional stratification by the annual
number of new patients treated with radiotherapy per institution. The estimated annual numbers of new and total
(new plus repeat) patients treated with radiation were 225 000 and 271 000, respectively. Additionally, the estimated
cancer incidence was 891 445 cases with approximately 25.2% of all newly diagnosed patients being treated with
radiation. The types and numbers of treatment devices actually used included linear accelerator (linac; n = 936),
Gamma Knife (n = 43), 60Co remote afterloading system (RALS; n = 21), and 192Ir RALS (n = 129). The linac
system used dual-energy functions in 754 units, 3D conformal radiotherapy functions in 867, and intensity-modulated
radiotherapy (IMRT) functions in 628. There were 899 Japan Radiological Society/Japanese Society for Radiation
Oncology-certified radiation oncologists (RO), 1213.9 full-time equivalent (FTE) ROs, 2394.2 FTE radiotherapy
technologists (RTT), 295.7 FTE medical physicists, 210.2 FTE radiotherapy quality managers, and 906.1 FTE nurses.
The frequency of IMRT use significantly increased during this time. In conclusion, the Japanese structure of radiation
oncology has clearly improved in terms of equipment and utility although there was a shortage of personnel in 2015.
書誌情報 Journal of Radiation Research

発行日 2024-01
PubMed番号
識別子タイプ PMID
関連識別子 35137180
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 02:18:09.965003
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3