Dual-Energy Computed Tomography-Based Iodine Concentration Estimation for Evaluating Choroidal Malignant Melanoma Response to Treatment: Optimization and Primary Validation

https://repo.qst.go.jp/records/2000290
https://repo.qst.go.jp/records/2000290
a6c43d21-0db6-4c82-8c56-15749b640061
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2023-09-04
タイトル
タイトル Dual-Energy Computed Tomography-Based Iodine Concentration Estimation for Evaluating Choroidal Malignant Melanoma Response to Treatment: Optimization and Primary Validation
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tsuchiya Hiroki

× Tsuchiya Hiroki

Tsuchiya Hiroki

Search repository
Tachibana Yasuhiko

× Tachibana Yasuhiko

Tachibana Yasuhiko

Search repository
Kishimoto Riwa

× Kishimoto Riwa

Kishimoto Riwa

Search repository
Omatsu Tokuhiko

× Omatsu Tokuhiko

Omatsu Tokuhiko

Search repository
Hotta Eika

× Hotta Eika

Hotta Eika

Search repository
Tanimoto Katsuyuki

× Tanimoto Katsuyuki

Tanimoto Katsuyuki

Search repository
Wakatsuki Masaru

× Wakatsuki Masaru

Wakatsuki Masaru

Search repository
Obata Takayuki

× Obata Takayuki

Obata Takayuki

Search repository
Tsuji Hiroshi

× Tsuji Hiroshi

Tsuji Hiroshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Contrast-enhanced imaging for choroidal malignant melanoma (CMM) is mostly limited to detecting metastatic tumors, possibly due to difficulties in fixing the eye position. We aimed to (1) validate the appropriateness of estimating iodine concentration based on dual-energy computed tomography (DECT) for CMM and optimize the calculation parameters for estimation, and (2) perform a primary clinical validation by assessing the ability of this technique to show changes in CMM after charged-particle radiation therapy. The accuracy of the optimized estimate (eIC_optimized) was compared to an estimate obtained by commercial software (eIC_commercial) by determining the difference from the ground truth. Then, eIC_optimized, tumor volume, and CT values (80 kVp, 140 kVp, and synthesized 120 kVp) were measured at pre-treatment and 3 months and 1.5?2 years after treatment. The difference from the ground truth was significantly smaller in eIC_optimized than in eIC_commercial (p < 0.01). Tumor volume, CT values, and eIC_optimized all decreased significantly at 1.5?2 years after treatment, but only eIC_commercial showed a significant reduction at 3 months after treatment (p < 0.01). eIC_optimized can quantify contrast enhancement in primary CMM lesions and has high sensitivity for detecting the response to charged-particle radiation therapy, making it potentially useful for treatment monitoring.
書誌情報 Diagnostics

巻 12, 号 11, p. 2692, 発行日 2022-11
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2075-4418
DOI
識別子タイプ DOI
関連識別子 10.3390/diagnostics12112692
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 01:52:52.591887
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3