ログイン
Language:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

?Comparative evaluation of radionuclide therapy using 90Y and 177Lu

https://repo.qst.go.jp/records/2000284
https://repo.qst.go.jp/records/2000284
a5d7c8cb-bb06-4322-b9c8-7d861d5f5585
アイテムタイプ 学術雑誌論文 / Journal Article(1)
公開日 2023-08-07
タイトル
タイトル ?Comparative evaluation of radionuclide therapy using 90Y and 177Lu
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Hirofumi Hanaoka (Gunma Univ)

× Hirofumi Hanaoka (Gunma Univ)

Hirofumi Hanaoka (Gunma Univ)

Search repository
Kazuyuki Hashimoto (JAEA)

× Kazuyuki Hashimoto (JAEA)

Kazuyuki Hashimoto (JAEA)

Search repository
Watanabe Satoshi

× Watanabe Satoshi

Watanabe Satoshi

Search repository
Matsumoto Shojiro

× Matsumoto Shojiro

Matsumoto Shojiro

Search repository
Sakashita Tetsuya

× Sakashita Tetsuya

Sakashita Tetsuya

Search repository
Watanabe Shigeki

× Watanabe Shigeki

Watanabe Shigeki

Search repository
Ishioka Noriko

× Ishioka Noriko

Ishioka Noriko

Search repository
Keigo Endo (Gunma Univ)

× Keigo Endo (Gunma Univ)

Keigo Endo (Gunma Univ)

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective Both 90Y and 177Lu are attractive β-emitters for radionuclide therapy and have been used in clinical practice.
Nevertheless, comparative evaluation between 90Y- and 177Lu-labeled molecules has not been fully conducted. Thus, in this
study, the features of 90Y and 177Lu for radionuclide therapy were assessed in tumor-bearing mice.
Methods Two tumor cell lines with different growth rates were used. Biodistribution studies of 177Lu-labeled antibodies
(177Lu-Abs) were conducted in each tumor-bearing mouse model. Subsequently, the therapeutic effect of 90Y- and 177Lu-
Ab were assessed in tumor-bearing mice. The absorbed radiation dose for the tumor was estimated using the Monte Carlo
simulation.
Results 177Lu-Abs demonstrated high tumor accumulation in both tumor-xerograph. In the fast-growing tumor model, 90Y-Ab
showed a better therapeutic effect than 177Lu-Ab, reflecting a higher absorbed radiation dose of 90Y-Ab than that of 177Lu-Ab.
In the slow-growing tumor model, both 90Y- and 177Lu-Ab showed an excellent therapeutic effect; however, 177Lu-Ab had
a longer efficacy period than 90Y-Ab, which could be attributed to the longer half-life and better dose uniformity of 177Lu
than those of 90Y.
Conclusions To accomplish a maximum therapeutic effect, selecting 90Y or 177Lu, to depend on the growth rate of individual
cancer, would be helpful.
書誌情報 Annals of Nuclear Medicine

巻 37, p. 52-59, 発行日 2022-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-022-01803-y
戻る
0
views
See details
Views

Versions

Ver.1 2025-08-15 01:52:41.187600
Show All versions

Share

Share
tweet

Cite as

Other

print

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX
  • ZIP

コミュニティ

確認

確認

確認


Powered by WEKO3


Powered by WEKO3