WEKO3
アイテム
{"_buckets": {"deposit": "d6d3a53b-06f9-4e0b-a3ea-667f3d224630"}, "_deposit": {"created_by": 1, "id": "84571", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "84571"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00084571", "sets": ["1"]}, "author_link": ["1020694", "1020693", "1020691", "1020689", "1020692", "1020695", "1020690"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageStart": "21696", "bibliographicVolumeNumber": "11", "bibliographic_titles": [{"bibliographic_title": "Scientific Reports"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Carbon ion radiotherapy is a sophisticated radiation treatment modality because of its superiority in achieving precise dosage distribution and high biological effectiveness. However, there exist beam range uncertainties that affect treatment efficiency. This problem can be resolved if the clinical beam could be monitored precisely in real-time, such as by imaging the prompt gamma emission from the target. In this study, we performed real-time detection and imaging of 718 keV prompt gamma emissions using a Si/CdTe Compton camera. We conducted experiments on graphite phantoms using clinical carbon ion beams of 290 MeV/u energy. Compton images were reconstructed using simple back-projection methods from the energy events of 718 keV prompt gamma emissions. The peak intensity position in reconstructed 718 keV prompt gamma images was few millimeters below the Bragg peak position. Moreover, the dual- and triple-energy window images for all positions of phantoms were not affected by scattered gammas, and their peak intensity positions were approximately similar to those observed in the reconstructed 718 keV prompt gamma images. In conclusion, the findings of the current study demonstrate the feasibility of using our Compton camera for real-time beam monitoring of carbon ion beams under clinical beam intensity.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "NATURE"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1038/s41598-021-00949-5", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.nature.com/articles/s41598-021-00949-5#citeas", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2045-2322", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Parajuli, Raj"}], "nameIdentifiers": [{"nameIdentifier": "1020689", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakai, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "1020690", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Arakawa, Kazuo"}], "nameIdentifiers": [{"nameIdentifier": "1020691", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kubota, Yoshiki"}], "nameIdentifiers": [{"nameIdentifier": "1020692", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kubo, Nobutero"}], "nameIdentifiers": [{"nameIdentifier": "1020693", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashiro, Matsumi"}], "nameIdentifiers": [{"nameIdentifier": "1020694", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Parajuli, Raj", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1020695", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Carbon Range Verification with 718 keV Compton Imaging", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Carbon Range Verification with 718 keV Compton Imaging"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/84571", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-11-05"}, "publish_date": "2021-11-05", "publish_status": "0", "recid": "84571", "relation": {}, "relation_version_is_last": true, "title": ["Carbon Range Verification with 718 keV Compton Imaging"], "weko_shared_id": -1}
Carbon Range Verification with 718 keV Compton Imaging
https://repo.qst.go.jp/records/84571
https://repo.qst.go.jp/records/845711db0647c-b5a5-482c-9e59-5d7a9762a5c7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-11-05 | |||||
タイトル | ||||||
タイトル | Carbon Range Verification with 718 keV Compton Imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Parajuli, Raj
× Parajuli, Raj× Sakai, Makoto× Arakawa, Kazuo× Kubota, Yoshiki× Kubo, Nobutero× Tashiro, Matsumi× Parajuli, Raj |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Carbon ion radiotherapy is a sophisticated radiation treatment modality because of its superiority in achieving precise dosage distribution and high biological effectiveness. However, there exist beam range uncertainties that affect treatment efficiency. This problem can be resolved if the clinical beam could be monitored precisely in real-time, such as by imaging the prompt gamma emission from the target. In this study, we performed real-time detection and imaging of 718 keV prompt gamma emissions using a Si/CdTe Compton camera. We conducted experiments on graphite phantoms using clinical carbon ion beams of 290 MeV/u energy. Compton images were reconstructed using simple back-projection methods from the energy events of 718 keV prompt gamma emissions. The peak intensity position in reconstructed 718 keV prompt gamma images was few millimeters below the Bragg peak position. Moreover, the dual- and triple-energy window images for all positions of phantoms were not affected by scattered gammas, and their peak intensity positions were approximately similar to those observed in the reconstructed 718 keV prompt gamma images. In conclusion, the findings of the current study demonstrate the feasibility of using our Compton camera for real-time beam monitoring of carbon ion beams under clinical beam intensity. | |||||
書誌情報 |
Scientific Reports 巻 11, p. 21696, 発行日 2021-11 |
|||||
出版者 | ||||||
出版者 | NATURE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2045-2322 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/s41598-021-00949-5 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.nature.com/articles/s41598-021-00949-5#citeas |