WEKO3
アイテム
{"_buckets": {"deposit": "3cafc2d3-b515-40e0-a17d-181d6b471fdc"}, "_deposit": {"created_by": 1, "id": "84562", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "84562"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00084562", "sets": ["1"]}, "author_link": ["1020574", "1020561", "1020569", "1020570", "1020572", "1020566", "1020568", "1020573", "1020563", "1020565", "1020560", "1020571", "1020567", "1020564", "1020562"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "4408", "bibliographicPageStart": "4398", "bibliographicVolumeNumber": "57", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Industry Applications"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This article presents the development results of a five-stage dc-1 MV rectifier for an international thermonuclear experimental reactor neutral beam injector system. Each rectifier outputs -200 kV, and the total five rectifiers are connected in a series. The feasibility of both gas insulation and gas cooling for semiconductor devices was validated to achieve dc-1 MV output and 1-h continuous operation. We devised a novel structure of cylindrical dense alignment of the heatsinks with stud-type diodes, which enables both the mitigation of electric-field concentration on the heatsinks and the improvement of heat dissipation from diodes. The difference in the temperature rise for three different directions of the heatsink in an SF 6 gas atmosphere was also clarified. The heat flow was analyzed to quantify the cooling effect of SF 6 gas, taking into account the gas circulation by the external cooling system. Rectification operation and temperature rise were tested with an actual-scale rectifier including a step-up transformer. Additionally, dc-1.2 MV withstand voltage was tested for a fifth-stage actual-scale rectifier. The test results demonstrated the validity of the proposed design.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/TIA.2021.3096775", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://ieeexplore.ieee.org/document/9484737", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0093-9994", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Akeshi Takahashi"}], "nameIdentifiers": [{"nameIdentifier": "1020560", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suto, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "1020561", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanaka, Toshiaki"}], "nameIdentifiers": [{"nameIdentifier": "1020562", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaguchi, Kohei"}], "nameIdentifiers": [{"nameIdentifier": "1020563", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroyuki Fujita"}], "nameIdentifiers": [{"nameIdentifier": "1020564", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiranuma, Yuki"}], "nameIdentifiers": [{"nameIdentifier": "1020565", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satoshi Ichimura"}], "nameIdentifiers": [{"nameIdentifier": "1020566", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kazuhiro, Watanabe"}], "nameIdentifiers": [{"nameIdentifier": "1020567", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mieko, Kashiwagi"}], "nameIdentifiers": [{"nameIdentifier": "1020568", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tetsuya, Maejima"}], "nameIdentifiers": [{"nameIdentifier": "1020569", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroyuki, Tobari"}], "nameIdentifiers": [{"nameIdentifier": "1020570", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kazuhiro, Watanabe", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1020571", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mieko, Kashiwagi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1020572", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tetsuya, Maejima", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1020573", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hiroyuki, Tobari", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1020574", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/84562", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-11-17"}, "publish_date": "2021-11-17", "publish_status": "0", "recid": "84562", "relation": {}, "relation_version_is_last": true, "title": ["1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System"], "weko_shared_id": -1}
1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System
https://repo.qst.go.jp/records/84562
https://repo.qst.go.jp/records/84562769fb1a4-37f8-4a60-a113-91818d4d193d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-11-17 | |||||
タイトル | ||||||
タイトル | 1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Akeshi Takahashi
× Akeshi Takahashi× Suto, Tetsuya× Tanaka, Toshiaki× Yamaguchi, Kohei× Hiroyuki Fujita× Hiranuma, Yuki× Satoshi Ichimura× Kazuhiro, Watanabe× Mieko, Kashiwagi× Tetsuya, Maejima× Hiroyuki, Tobari× Kazuhiro, Watanabe× Mieko, Kashiwagi× Tetsuya, Maejima× Hiroyuki, Tobari |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This article presents the development results of a five-stage dc-1 MV rectifier for an international thermonuclear experimental reactor neutral beam injector system. Each rectifier outputs -200 kV, and the total five rectifiers are connected in a series. The feasibility of both gas insulation and gas cooling for semiconductor devices was validated to achieve dc-1 MV output and 1-h continuous operation. We devised a novel structure of cylindrical dense alignment of the heatsinks with stud-type diodes, which enables both the mitigation of electric-field concentration on the heatsinks and the improvement of heat dissipation from diodes. The difference in the temperature rise for three different directions of the heatsink in an SF 6 gas atmosphere was also clarified. The heat flow was analyzed to quantify the cooling effect of SF 6 gas, taking into account the gas circulation by the external cooling system. Rectification operation and temperature rise were tested with an actual-scale rectifier including a step-up transformer. Additionally, dc-1.2 MV withstand voltage was tested for a fifth-stage actual-scale rectifier. The test results demonstrated the validity of the proposed design. | |||||
書誌情報 |
IEEE Transactions on Industry Applications 巻 57, 号 5, p. 4398-4408, 発行日 2021-09 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0093-9994 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TIA.2021.3096775 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ieeexplore.ieee.org/document/9484737 |