ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Dose quantification in carbon ion therapy using in-beam positron emission tomography

https://repo.qst.go.jp/records/81514
https://repo.qst.go.jp/records/81514
7f088e07-0144-47cf-9435-d09069356fb0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-12-24
タイトル
タイトル Dose quantification in carbon ion therapy using in-beam positron emission tomography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Rutherford, Harley

× Rutherford, Harley

WEKO 1013608

Rutherford, Harley

Search repository
Chacon, Andrew

× Chacon, Andrew

WEKO 1013609

Chacon, Andrew

Search repository
Mohammadi, Akram

× Mohammadi, Akram

WEKO 1013610

Mohammadi, Akram

Search repository
Takyu, Sodai

× Takyu, Sodai

WEKO 1013611

Takyu, Sodai

Search repository
Tashima, Hideaki

× Tashima, Hideaki

WEKO 1013612

Tashima, Hideaki

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 1013613

Yoshida, Eiji

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 1013614

Nishikido, Fumihiko

Search repository
Hofmann, Teresa

× Hofmann, Teresa

WEKO 1013615

Hofmann, Teresa

Search repository
Pinto, Marco

× Pinto, Marco

WEKO 1013616

Pinto, Marco

Search repository
R Franklin, Daniel

× R Franklin, Daniel

WEKO 1013617

R Franklin, Daniel

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 1013618

Yamaya, Taiga

Search repository
Parodi, Katia

× Parodi, Katia

WEKO 1013619

Parodi, Katia

Search repository
B Rosenfeld, Anatoly

× B Rosenfeld, Anatoly

WEKO 1013620

B Rosenfeld, Anatoly

Search repository
Guatelli, Susanna

× Guatelli, Susanna

WEKO 1013621

Guatelli, Susanna

Search repository
Safavi naeini, Mitra

× Safavi naeini, Mitra

WEKO 1013622

Safavi naeini, Mitra

Search repository
Rutherford, Harley

× Rutherford, Harley

WEKO 1013623

en Rutherford, Harley

Search repository
Chacon, Andrew

× Chacon, Andrew

WEKO 1013624

en Chacon, Andrew

Search repository
Mohammadi, Akram

× Mohammadi, Akram

WEKO 1013625

en Mohammadi, Akram

Search repository
Sodai, Takyu

× Sodai, Takyu

WEKO 1013626

en Sodai, Takyu

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1013627

en Hideaki, Tashima

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 1013628

en Eiji, Yoshida

Search repository
Fumihiko, Nishikido

× Fumihiko, Nishikido

WEKO 1013629

en Fumihiko, Nishikido

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1013630

en Taiga, Yamaya

Search repository
Parodi, Katia

× Parodi, Katia

WEKO 1013631

en Parodi, Katia

Search repository
Safavi naeini, Mitra

× Safavi naeini, Mitra

WEKO 1013632

en Safavi naeini, Mitra

Search repository
抄録
内容記述タイプ Abstract
内容記述 This work presents an iterative method for the estimation of the absolute dose distribution in patients undergoing carbon ion therapy, via analysis of the distribution of positron annihilations resulting from the decay of positron-emitting fragments created in the target volume. The proposed method relies on the decomposition of the total positron-annihilation distributions into profiles of the three principal positron-emitting fragment species - 11C, 10C and 15O. A library of basis functions is constructed by simulating a range of monoenergetic 12C ion irradiations of a homogeneous polymethyl methacrylate phantom and measuring the resulting one-dimensional positron-emitting fragment profiles and dose distributions. To estimate the dose delivered during an arbitrary polyenergetic irradiation, a linear combination of factors from the fragment profile
library is iteratively fitted to the decomposed positron annihilation profile acquired during the irradiation, and the resulting weights combined with the corresponding monoenergetic dose profiles to estimate the total dose distribution. A total variation regularisation term is incorporated into the fitting process to suppress high-frequency noise. The method was evaluated with 14
different polyenergetic 12C dose profiles in a polymethyl methacrylate target: one which produces a flat biological dose, 10 with randomised energy weighting factors, and three with distinct dose maxima or minima within the spread-out Bragg peak region. The proposed method is able to calculate the dose profile with mean relative errors of 0.8%, 1.0% and 1.6% from the 11C, 10C, 15O
fragment profiles, respectively, and estimate the position of the distal edge of the SOBP to within an average of 0.7 mm, 1.9 mm and 1.2 mm of its true location.
書誌情報 Physics in Medicine & Biology

巻 65, 号 23, p. 235052, 発行日 2020-12
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/abaa23
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1088/1361-6560/abaa23
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:18:01.878991
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3