WEKO3
アイテム
{"_buckets": {"deposit": "cf292829-1054-4ea0-8a3a-25f7eb131b04"}, "_deposit": {"created_by": 1, "id": "80098", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80098"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080098", "sets": ["1"]}, "author_link": ["916932", "916931", "916926", "916936", "916927", "916925", "916928", "916933", "916937", "916929", "916934", "916935", "916930"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "125013-15", "bibliographicPageStart": "125013-1", "bibliographicVolumeNumber": "65", "bibliographic_titles": [{"bibliographic_title": "Physics in Medicine \u0026 Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We proposed a concept of whole gamma imaging (WGI) that utilizes all detectable gamma rays for imaging. An additional detector ring, which is used as the scatterer, is inserted in the field-of-view of a PET ring so that single gamma rays can be detected by the Compton imaging method. In particular, for the non-pure positron emitters which emit an additional gamma ray almost at the\nsame time, triple gamma imaging will be enabled; localization on each line-of-response (LOR) is possible by using the Compton cone of the additional gamma ray. We developed a prototype to show a proof of the WGI concept. The diameters of scatterer ring and PET ring were set as 20 cm and 66 cm, respectively. For Compton imaging of the 662-keV gamma ray from a 137Cs point source, spatial resolution obtained by the list-mode OSEM algorithm was 4.4 mm FWHM at the 8 cm off-center position and 13.1 mm FWHM at the center position. For PET imaging of a 22Na point source, spatial resolution was about 2 mm FWHM at all positions. For the triple gamma imaging, 5.7 mm FWHM (center) and 4.8 mm FWHM (8 cm off-center) were obtained for the\n22Na point source just by plotting the intersecting points between each LOR and each Compton cone of the 1275-keV gamma ray. No image reconstruction was applied. Scandium-44 was produced as a practical candidate of the non-pure positron emitters, and 6.6 mm FWHM (center) and 5.8 mm FWHM (8 cm off-center) were obtained in the same manner. This direct imaging approach which neither requires time-consuming event integration nor iterative image\nreconstruction may allow in vivo real-time tracking of a tiny amount of activity. Our initial results showed the feasibility of the WGI concept, which is a novel combination of PET and Compton imaging.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IOP Publishing"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1088/1361-6560/ab8e89", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1088/1361-6560/ab8e89", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-9155", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yoshida, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "916925", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "916926", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagatsu, Kotaro"}], "nameIdentifiers": [{"nameIdentifier": "916927", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuji, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "916928", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kamada, Kei"}], "nameIdentifiers": [{"nameIdentifier": "916929", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Parodi, Katia"}], "nameIdentifiers": [{"nameIdentifier": "916930", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "916931", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Eiji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "916932", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tashima, Hideaki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "916933", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagatsu, Kotaro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "916934", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsuji, Atsushi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "916935", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Parodi, Katia", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "916936", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "916937", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Whole gamma imaging: a new concept of PET combined with Compton", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Whole gamma imaging: a new concept of PET combined with Compton"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/80098", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-06-19"}, "publish_date": "2020-06-19", "publish_status": "0", "recid": "80098", "relation": {}, "relation_version_is_last": true, "title": ["Whole gamma imaging: a new concept of PET combined with Compton"], "weko_shared_id": -1}
Whole gamma imaging: a new concept of PET combined with Compton
https://repo.qst.go.jp/records/80098
https://repo.qst.go.jp/records/80098cddc2521-31f4-49dd-a36f-c17ab7eb2ff7
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-06-19 | |||||
タイトル | ||||||
タイトル | Whole gamma imaging: a new concept of PET combined with Compton | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× Tashima, Hideaki× Nagatsu, Kotaro× Tsuji, Atsushi× Kamada, Kei× Parodi, Katia× Yamaya, Taiga× Yoshida, Eiji× Tashima, Hideaki× Nagatsu, Kotaro× Tsuji, Atsushi× Parodi, Katia× Yamaya, Taiga |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We proposed a concept of whole gamma imaging (WGI) that utilizes all detectable gamma rays for imaging. An additional detector ring, which is used as the scatterer, is inserted in the field-of-view of a PET ring so that single gamma rays can be detected by the Compton imaging method. In particular, for the non-pure positron emitters which emit an additional gamma ray almost at the same time, triple gamma imaging will be enabled; localization on each line-of-response (LOR) is possible by using the Compton cone of the additional gamma ray. We developed a prototype to show a proof of the WGI concept. The diameters of scatterer ring and PET ring were set as 20 cm and 66 cm, respectively. For Compton imaging of the 662-keV gamma ray from a 137Cs point source, spatial resolution obtained by the list-mode OSEM algorithm was 4.4 mm FWHM at the 8 cm off-center position and 13.1 mm FWHM at the center position. For PET imaging of a 22Na point source, spatial resolution was about 2 mm FWHM at all positions. For the triple gamma imaging, 5.7 mm FWHM (center) and 4.8 mm FWHM (8 cm off-center) were obtained for the 22Na point source just by plotting the intersecting points between each LOR and each Compton cone of the 1275-keV gamma ray. No image reconstruction was applied. Scandium-44 was produced as a practical candidate of the non-pure positron emitters, and 6.6 mm FWHM (center) and 5.8 mm FWHM (8 cm off-center) were obtained in the same manner. This direct imaging approach which neither requires time-consuming event integration nor iterative image reconstruction may allow in vivo real-time tracking of a tiny amount of activity. Our initial results showed the feasibility of the WGI concept, which is a novel combination of PET and Compton imaging. |
|||||
書誌情報 |
Physics in Medicine & Biology 巻 65, 号 12, p. 125013-1-125013-15, 発行日 2020-06 |
|||||
出版者 | ||||||
出版者 | IOP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1361-6560/ab8e89 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/1361-6560/ab8e89 |