{"_buckets": {"deposit": "6f77e25c-3e6f-460c-a0a2-63facc8751be"}, "_deposit": {"created_by": 1, "id": "79550", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "79550"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00079550", "sets": ["28"]}, "author_link": ["856369", "856364", "856365", "856363", "856367", "856368", "856366"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-12-17", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The nitrogen-vacancy center in diamond is an exquisite solid-state sensor based upon quantum nature. Numerous studies have shown that dynamical decoupling, such as an XY8 sequence, provides us a high sensitivity for an oscillating magnetic field parametrized by amplitude and phase. However, there are some drawbacks. (1) A measurement using XY8 requires a careful adjustment of timings between XY8 sequences and the target signal. (2) The XY8 has an intricate dependence on both parameters, so it is not applicable in a situation that both parameters simultaneously change. (3) It is impossible to measure both parameters simultaneous, and they have to be measured severally. In this study, we present that Qdyne1-3, a quantum-classical hybrid protocol, solves them, consisted of sequential and stroboscopic measurements. The Qdyne does not require a timing adjustment before itself, has an intuitive dependency on both parameters, and let us a simultaneous measurement of both amplitude and phase. Moreover, we implemented it on a widefield of view. The large observation area of widefield modality and the high spatial resolution of NV center pave the way for a tiny-scale inspection by Eddy-current, which established sensors cannot detect.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The 2nd International Forum on Quantum Metrology and Sensing への出席", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mizuno, Kosuke"}], "nameIdentifiers": [{"nameIdentifier": "856363", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishiwata, Hitoshi"}], "nameIdentifiers": [{"nameIdentifier": "856364", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masuyama, Yuta"}], "nameIdentifiers": [{"nameIdentifier": "856365", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwasaki, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "856366", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatano, Mutsuko"}], "nameIdentifiers": [{"nameIdentifier": "856367", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masuyama, Yuta", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "856368", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatano, Mutsuko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "856369", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/79550", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-03-18"}, "publish_date": "2020-03-18", "publish_status": "0", "recid": "79550", "relation": {}, "relation_version_is_last": true, "title": ["Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup"], "weko_shared_id": -1}
Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup
https://repo.qst.go.jp/records/79550
https://repo.qst.go.jp/records/79550593e5de5-eeeb-432e-ac0e-e759aed16644
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-03-18 | |||||
タイトル | ||||||
タイトル | Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizuno, Kosuke
× Mizuno, Kosuke× Ishiwata, Hitoshi× Masuyama, Yuta× Iwasaki, Takayuki× Hatano, Mutsuko× Masuyama, Yuta× Hatano, Mutsuko |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The nitrogen-vacancy center in diamond is an exquisite solid-state sensor based upon quantum nature. Numerous studies have shown that dynamical decoupling, such as an XY8 sequence, provides us a high sensitivity for an oscillating magnetic field parametrized by amplitude and phase. However, there are some drawbacks. (1) A measurement using XY8 requires a careful adjustment of timings between XY8 sequences and the target signal. (2) The XY8 has an intricate dependence on both parameters, so it is not applicable in a situation that both parameters simultaneously change. (3) It is impossible to measure both parameters simultaneous, and they have to be measured severally. In this study, we present that Qdyne1-3, a quantum-classical hybrid protocol, solves them, consisted of sequential and stroboscopic measurements. The Qdyne does not require a timing adjustment before itself, has an intuitive dependency on both parameters, and let us a simultaneous measurement of both amplitude and phase. Moreover, we implemented it on a widefield of view. The large observation area of widefield modality and the high spatial resolution of NV center pave the way for a tiny-scale inspection by Eddy-current, which established sensors cannot detect. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The 2nd International Forum on Quantum Metrology and Sensing への出席 | |||||
発表年月日 | ||||||
日付 | 2019-12-17 | |||||
日付タイプ | Issued |