ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Characterization and validation of multimodal annihilation-gamma/nearinfrared/visible laparoscopic system

https://repo.qst.go.jp/records/78094
https://repo.qst.go.jp/records/78094
fe628fa6-d57c-4996-a6f4-755b67e350c6
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-12-19
タイトル
タイトル Characterization and validation of multimodal annihilation-gamma/nearinfrared/visible laparoscopic system
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hyun Song, Seong

× Hyun Song, Seong

WEKO 1001999

Hyun Song, Seong

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 1002000

Kang, Hangyu

Search repository
Been Han, Young

× Been Han, Young

WEKO 1002001

Been Han, Young

Search repository
Ho-Young, Lee

× Ho-Young, Lee

WEKO 1002002

Ho-Young, Lee

Search repository
Hong Jeong, Dae

× Hong Jeong, Dae

WEKO 1002003

Hong Jeong, Dae

Search repository
Me Kim, Soo

× Me Kim, Soo

WEKO 1002004

Me Kim, Soo

Search repository
Jong Hong, Seong

× Jong Hong, Seong

WEKO 1002005

Jong Hong, Seong

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 1002006

en Kang, Hangyu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Minimally invasive robotic surgery using fluorescence-guided images with a video laparoscope has been widely used because of its advantages of small incision, fast recovery time, and efficiency. However, the penetrationdepthlimitationoffluorescenceisadisadvantagecausedbytheabsorptionandscatteringintissues andbloodcells.Ifthislimitationcanbeovercomebyadditionalimagingmodalities,thesurgicalprocedurecanbe quiteefficient and precise. High-energy annihilation-gamma photonshavea stronger penetration capabilitythan visible and fluorescence photons. To characterize and validate a multimodal annihilation-gamma/near-infrared (NIR)/visible laparoscopic imaging system, an internal detector composed of an annihilation-gamma detector and an optical system was assembled inside a surgical stainless pipe with an outer diameter of 15.8 mm and an external detector with a dimension of 100×100 mm2 placed at the opposite side of the internal detector. Integrated images of 511-keV gamma rays, NIR fluorescence, and visible light were obtained simultaneously. The 511-keV gamma image could be clearly seen with the acquisition of 5 s, while NIR and visible images could be presented in real time. This multimodal system has the potential for improving the surgery time and the quality of patient care.
書誌情報 Journal of Biomedical Optics

巻 24, 号 9, p. 096008, 発行日 2019-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 1083-3668
PubMed番号
識別子タイプ PMID
関連識別子 31564072
DOI
識別子タイプ DOI
関連識別子 10.1117/1.JBO.24.9.096008
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1117/1.JBO.24.9.096008
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:30:03.820452
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3