{"created":"2023-05-15T14:57:32.508284+00:00","id":78094,"links":{},"metadata":{"_buckets":{"deposit":"392d7686-7de2-4926-a8e9-09664abf893a"},"_deposit":{"created_by":1,"id":"78094","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"78094"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00078094","sets":["1"]},"author_link":["1002002","1002004","1002005","1002006","1002000","1002001","1001999","1002003"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"9","bibliographicPageStart":"096008","bibliographicVolumeNumber":"24","bibliographic_titles":[{"bibliographic_title":"Journal of Biomedical Optics"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Minimally invasive robotic surgery using fluorescence-guided images with a video laparoscope has been widely used because of its advantages of small incision, fast recovery time, and efficiency. However, the penetrationdepthlimitationoffluorescenceisadisadvantagecausedbytheabsorptionandscatteringintissues andbloodcells.Ifthislimitationcanbeovercomebyadditionalimagingmodalities,thesurgicalprocedurecanbe quiteefficient and precise. High-energy annihilation-gamma photonshavea stronger penetration capabilitythan visible and fluorescence photons. To characterize and validate a multimodal annihilation-gamma/near-infrared (NIR)/visible laparoscopic imaging system, an internal detector composed of an annihilation-gamma detector and an optical system was assembled inside a surgical stainless pipe with an outer diameter of 15.8 mm and an external detector with a dimension of 100×100 mm2 placed at the opposite side of the internal detector. Integrated images of 511-keV gamma rays, NIR fluorescence, and visible light were obtained simultaneously. The 511-keV gamma image could be clearly seen with the acquisition of 5 s, while NIR and visible images could be presented in real time. This multimodal system has the potential for improving the surgery time and the quality of patient care. ","subitem_description_type":"Abstract"}]},"item_8_relation_13":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"31564072 ","subitem_relation_type_select":"PMID"}}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1117/1.JBO.24.9.096008","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1117/1.JBO.24.9.096008","subitem_relation_type_select":"DOI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1083-3668","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hyun Song, Seong"}],"nameIdentifiers":[{"nameIdentifier":"1001999","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kang, Hangyu"}],"nameIdentifiers":[{"nameIdentifier":"1002000","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Been Han, Young"}],"nameIdentifiers":[{"nameIdentifier":"1002001","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ho-Young, Lee"}],"nameIdentifiers":[{"nameIdentifier":"1002002","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hong Jeong, Dae"}],"nameIdentifiers":[{"nameIdentifier":"1002003","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Me Kim, Soo"}],"nameIdentifiers":[{"nameIdentifier":"1002004","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Jong Hong, Seong"}],"nameIdentifiers":[{"nameIdentifier":"1002005","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kang, Hangyu","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1002006","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Characterization and validation of multimodal annihilation-gamma/nearinfrared/visible laparoscopic system","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Characterization and validation of multimodal annihilation-gamma/nearinfrared/visible laparoscopic system"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-12-19"},"publish_date":"2019-12-19","publish_status":"0","recid":"78094","relation_version_is_last":true,"title":["Characterization and validation of multimodal annihilation-gamma/nearinfrared/visible laparoscopic system"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:35:44.382177+00:00"}