{"_buckets": {"deposit": "520b1acf-0a3a-4c4b-8d48-c035112658aa"}, "_deposit": {"created_by": 1, "id": "78029", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "78029"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00078029", "sets": ["28"]}, "author_link": ["813596", "813598", "813597", "813599", "813600", "813595"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-11-29", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The precise isotope measurement of Te in terrestrial and extraterrestrial material is essential to check the isotopic heterogeneities attributable to incomplete mixing of r and s-processes products. MC-ICP-MS measurement has improved in accuracy and precision compared to NTIMS due to ionization of a greater proportion of Te atoms. Therefore, in the present study, we report Te isotope composition of terrestrial standards using NTIMS and MC-ICP-MS to check the precision and reproducibility of both instruments. Especially the use of 1012 Ω resistor for 120Te\nisotope in MC-ICP-MS enhanced the reproducibility and increased the result of\n120Te/128Te ratio by one order magnitude compare to the NTIMS data and previous studies. Thus, it illustrates that the MC-ICP-MS and NTIMS produce better precision and reproducibility for Te isotope ratio measurement. ", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "32nd ISMAS Symposium on Mass Spectrometry", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "M.Rajamanickam"}], "nameIdentifiers": [{"nameIdentifier": "813595", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "T.Aono"}], "nameIdentifiers": [{"nameIdentifier": "813596", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "S.K.Sahoo"}], "nameIdentifiers": [{"nameIdentifier": "813597", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murugan, Rajamanickam", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813598", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aono, Tatsuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813599", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sahoo, Sarata", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813600", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Precise determination of Tellurium isotope ratios by negative thermal ionization mass spectrometry and multi collector inductively coupled mass spectrometry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Precise determination of Tellurium isotope ratios by negative thermal ionization mass spectrometry and multi collector inductively coupled mass spectrometry"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/78029", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-12-12"}, "publish_date": "2019-12-12", "publish_status": "0", "recid": "78029", "relation": {}, "relation_version_is_last": true, "title": ["Precise determination of Tellurium isotope ratios by negative thermal ionization mass spectrometry and multi collector inductively coupled mass spectrometry"], "weko_shared_id": -1}
Precise determination of Tellurium isotope ratios by negative thermal ionization mass spectrometry and multi collector inductively coupled mass spectrometry
https://repo.qst.go.jp/records/78029
https://repo.qst.go.jp/records/780292709c158-c855-4887-9b96-7eb0a4be3fcf
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-12-12 | |||||
タイトル | ||||||
タイトル | Precise determination of Tellurium isotope ratios by negative thermal ionization mass spectrometry and multi collector inductively coupled mass spectrometry | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
M.Rajamanickam
× M.Rajamanickam× T.Aono× S.K.Sahoo× Murugan, Rajamanickam× Aono, Tatsuo× Sahoo, Sarata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The precise isotope measurement of Te in terrestrial and extraterrestrial material is essential to check the isotopic heterogeneities attributable to incomplete mixing of r and s-processes products. MC-ICP-MS measurement has improved in accuracy and precision compared to NTIMS due to ionization of a greater proportion of Te atoms. Therefore, in the present study, we report Te isotope composition of terrestrial standards using NTIMS and MC-ICP-MS to check the precision and reproducibility of both instruments. Especially the use of 1012 Ω resistor for 120Te isotope in MC-ICP-MS enhanced the reproducibility and increased the result of 120Te/128Te ratio by one order magnitude compare to the NTIMS data and previous studies. Thus, it illustrates that the MC-ICP-MS and NTIMS produce better precision and reproducibility for Te isotope ratio measurement. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 32nd ISMAS Symposium on Mass Spectrometry | |||||
発表年月日 | ||||||
日付 | 2019-11-29 | |||||
日付タイプ | Issued |