WEKO3
アイテム
{"_buckets": {"deposit": "4befddce-7f8f-4e16-b763-7d6e9894fa24"}, "_deposit": {"created_by": 1, "id": "74607", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "74607"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00074607", "sets": ["2"]}, "author_link": ["727313", "727315", "727310", "727318", "727311", "727316", "727317", "727314", "727312", "727319"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "93", "bibliographicPageStart": "89", "bibliographicVolumeNumber": "2017", "bibliographic_titles": [{"bibliographic_title": "第89回レーザ加工学会講演論文集"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "超伝導トカマク装置JT-60SAでは、真空容器内部が放射線環境となるため、真空容器内機器を交換・修理する際に、遠隔操作で冷却水配管の切断・再溶接を行う必要がある。JT-60SAのダイバータカセット内の配管と真空容器側の接続部を溶接するために、冷却水配管(SUS316L製、内径φ54.2 mm、肉厚2.8 mm) の内部から円周溶接が可能な溶接ヘッドを開発し、溶接試験を行った。配管突合せ部のギャップ対策として、上管の内径側に円周状の突起を設け、それをレーザで溶融して、ギャップを埋めることにより、初期ギャップ0.5mmにおいても、肉厚の減肉を最小限に抑え、信頼性の高い溶接を実現した。また、配管に傾きがある場合には、ツールの回転と上下位置を連動させることにより、レーザの狙い位置のずれを0.1mm以下に抑えて、0.5度の傾きがある配管でも溶接できることを明らかにし、実機で溶接できる見通しを得た。", "subitem_description_type": "Abstract"}]}, "item_8_relation_10": {"attribute_name": "ISBN", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "978-4-947684-90-5", "subitem_relation_type_select": "ISBN"}}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "林, 孝夫"}], "nameIdentifiers": [{"nameIdentifier": "727310", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "櫻井, 真治"}], "nameIdentifiers": [{"nameIdentifier": "727311", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武智, 学"}], "nameIdentifiers": [{"nameIdentifier": "727312", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鶴, 大悟"}], "nameIdentifiers": [{"nameIdentifier": "727313", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松永, 剛"}], "nameIdentifiers": [{"nameIdentifier": "727314", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "林 孝夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "727315", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "櫻井 真治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "727316", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武智 学", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "727317", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鶴 大悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "727318", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松永 剛", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "727319", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "超伝導トカマク装置JT-60SAにおける真空容器内機器保守に向けたレーザ溶接ツールの開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "超伝導トカマク装置JT-60SAにおける真空容器内機器保守に向けたレーザ溶接ツールの開発"}]}, "item_type_id": "8", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/74607", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-01"}, "publish_date": "2019-03-01", "publish_status": "0", "recid": "74607", "relation": {}, "relation_version_is_last": true, "title": ["超伝導トカマク装置JT-60SAにおける真空容器内機器保守に向けたレーザ溶接ツールの開発"], "weko_shared_id": -1}
超伝導トカマク装置JT-60SAにおける真空容器内機器保守に向けたレーザ溶接ツールの開発
https://repo.qst.go.jp/records/74607
https://repo.qst.go.jp/records/746078eac6e2f-5f9a-4d3b-8530-bb6125f9868d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-01 | |||||
タイトル | ||||||
タイトル | 超伝導トカマク装置JT-60SAにおける真空容器内機器保守に向けたレーザ溶接ツールの開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
林, 孝夫
× 林, 孝夫× 櫻井, 真治× 武智, 学× 鶴, 大悟× 松永, 剛× 林 孝夫× 櫻井 真治× 武智 学× 鶴 大悟× 松永 剛 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 超伝導トカマク装置JT-60SAでは、真空容器内部が放射線環境となるため、真空容器内機器を交換・修理する際に、遠隔操作で冷却水配管の切断・再溶接を行う必要がある。JT-60SAのダイバータカセット内の配管と真空容器側の接続部を溶接するために、冷却水配管(SUS316L製、内径φ54.2 mm、肉厚2.8 mm) の内部から円周溶接が可能な溶接ヘッドを開発し、溶接試験を行った。配管突合せ部のギャップ対策として、上管の内径側に円周状の突起を設け、それをレーザで溶融して、ギャップを埋めることにより、初期ギャップ0.5mmにおいても、肉厚の減肉を最小限に抑え、信頼性の高い溶接を実現した。また、配管に傾きがある場合には、ツールの回転と上下位置を連動させることにより、レーザの狙い位置のずれを0.1mm以下に抑えて、0.5度の傾きがある配管でも溶接できることを明らかにし、実機で溶接できる見通しを得た。 | |||||
書誌情報 |
第89回レーザ加工学会講演論文集 巻 2017, 号 10, p. 89-93, 発行日 2018-05 |
|||||
ISBN | ||||||
識別子タイプ | ISBN | |||||
関連識別子 | 978-4-947684-90-5 |