{"_buckets": {"deposit": "1376b232-9b44-48c1-9c3f-3789690ac370"}, "_deposit": {"created_by": 1, "id": "72827", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "72827"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00072827", "sets": ["28"]}, "author_link": ["717451", "717452", "717455", "717454", "717450", "717453"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2018-06-19", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "PET insert for the existing MRI systems can be a potential affordable alternative of body PET/MRI system. To avoid mutual interference between PET front-end electronics and the MRI system, PET front-end (F/E) electronics are enclosed in RF shielded Faraday cage that is connected to the RF ground for shielding purpose. On the other hand, strip transmission line RF coil requires a grounded plane in parallel with a strip conductor as coil that are connected by shunt capacitors. In this study, we proposed a strip transmission line coil that replaced the ground one layer conductor with the shielded PET detector module. The combined system shows promise for a compact PET/RF coil modality as insert for simultaneous PET/MR imaging with existing MRI systems, suitable even at ultrahigh field MRI.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "ISMRM 2018 Annual Meeting", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hossain, Akram"}], "nameIdentifiers": [{"nameIdentifier": "717450", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "717451", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamaya, Taiga"}], "nameIdentifiers": [{"nameIdentifier": "717452", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Md Shahadat Hossain Akram", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "717453", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "717454", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山谷 泰賀", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "717455", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Strip transmission line coil combined with RF shielded PET detector for existing MRI systems", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Strip transmission line coil combined with RF shielded PET detector for existing MRI systems"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/72827", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-06-15"}, "publish_date": "2018-06-15", "publish_status": "0", "recid": "72827", "relation": {}, "relation_version_is_last": true, "title": ["Strip transmission line coil combined with RF shielded PET detector for existing MRI systems"], "weko_shared_id": -1}
Strip transmission line coil combined with RF shielded PET detector for existing MRI systems
https://repo.qst.go.jp/records/72827
https://repo.qst.go.jp/records/72827e40ddd07-cff7-4252-b8a4-240ad4b56802
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-06-15 | |||||
タイトル | ||||||
タイトル | Strip transmission line coil combined with RF shielded PET detector for existing MRI systems | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hossain, Akram
× Hossain, Akram× Obata, Takayuki× Yamaya, Taiga× Md Shahadat Hossain Akram× 小畠 隆行× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | PET insert for the existing MRI systems can be a potential affordable alternative of body PET/MRI system. To avoid mutual interference between PET front-end electronics and the MRI system, PET front-end (F/E) electronics are enclosed in RF shielded Faraday cage that is connected to the RF ground for shielding purpose. On the other hand, strip transmission line RF coil requires a grounded plane in parallel with a strip conductor as coil that are connected by shunt capacitors. In this study, we proposed a strip transmission line coil that replaced the ground one layer conductor with the shielded PET detector module. The combined system shows promise for a compact PET/RF coil modality as insert for simultaneous PET/MR imaging with existing MRI systems, suitable even at ultrahigh field MRI. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | ISMRM 2018 Annual Meeting | |||||
発表年月日 | ||||||
日付 | 2018-06-19 | |||||
日付タイプ | Issued |