{"created":"2023-05-15T14:53:28.755171+00:00","id":72827,"links":{},"metadata":{"_buckets":{"deposit":"1376b232-9b44-48c1-9c3f-3789690ac370"},"_deposit":{"created_by":1,"id":"72827","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72827"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072827","sets":["10:28"]},"author_link":["717451","717452","717455","717454","717450","717453"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2018-06-19","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"PET insert for the existing MRI systems can be a potential affordable alternative of body PET/MRI system. To avoid mutual interference between PET front-end electronics and the MRI system, PET front-end (F/E) electronics are enclosed in RF shielded Faraday cage that is connected to the RF ground for shielding purpose. On the other hand, strip transmission line RF coil requires a grounded plane in parallel with a strip conductor as coil that are connected by shunt capacitors. In this study, we proposed a strip transmission line coil that replaced the ground one layer conductor with the shielded PET detector module. The combined system shows promise for a compact PET/RF coil modality as insert for simultaneous PET/MR imaging with existing MRI systems, suitable even at ultrahigh field MRI.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"ISMRM 2018 Annual Meeting","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hossain, Akram"}],"nameIdentifiers":[{"nameIdentifier":"717450","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Obata, Takayuki"}],"nameIdentifiers":[{"nameIdentifier":"717451","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaya, Taiga"}],"nameIdentifiers":[{"nameIdentifier":"717452","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Md Shahadat Hossain Akram","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"717453","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小畠 隆行","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"717454","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷 泰賀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"717455","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Strip transmission line coil combined with RF shielded PET detector for existing MRI systems","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Strip transmission line coil combined with RF shielded PET detector for existing MRI systems"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-06-15"},"publish_date":"2018-06-15","publish_status":"0","recid":"72827","relation_version_is_last":true,"title":["Strip transmission line coil combined with RF shielded PET detector for existing MRI systems"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:35:37.749605+00:00"}