WEKO3
アイテム
{"_buckets": {"deposit": "fea1eba1-5a68-4e35-9801-df332d86e881"}, "_deposit": {"created_by": 1, "id": "71665", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "71665"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00071665", "sets": ["28"]}, "author_link": ["705148", "705145", "705147", "705150", "705154", "705152", "705149", "705153", "705151", "705146"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2015-05-28", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Since 1994, a Phase I/II clinical study and radiotherapy have been carrying out using carbon-ion beams generated with the Heavy Ion Medical Accelerator in Chiba (HIMAC) at National Institute of Radiological Sciences. Now we constructed the new treatment facility for the advanced carbon-ion therapy applying a 3D fast spot scanning system with pencil beams. To identify the biological effects of a spot scanning carbon-ion beams in vitro, we demonstrated cell-killing effect of human tumor cell lines using the spot scanning irradiation of carbon-ion microbeams generated with the Takasaki Ion Accelerators for Advanced Radiation Application (TIARA) in Japan Atomic Energy Agency. We irradiated either 4-cell lines with wild-type P53 or 4-cell lines with mutated-type P53 using the TIARA microbeams collimated by 20µm in diameter. We can easily estimate the number of the directly irradiated cells to be 0.01% level of the total cells on the dish using the highly controlled microbeam irradiation system. The percent survival in the cells with wild-type P53 was around 90%, while almost 100% was observed in the cells with mutated-type P53. We can expect the percent survival of 99.99% level when the cell-killing effect was induced in directly irradiated 0.01% cells, assuming no bystander effect. However, the percent in the cells with wild-type P53 was significantly low beyond our expectation. Moreover, the percent returned to 100% when using a specific inhibitor of gap-junction mediated cell-cell communication. The results are consistent with the data using the carbon-ion broad beams with the shielding method at HIMAC, which irradiation was carried out using 4 different protocols; (1) All cells were irradiated; (2) Irradiated and unirradiated cells were pooled in a 1:1 ratio as a single culture; (3) Half of cells were irradiated using beam stopper; and (4) Half of cells were irradiated with a specific inhibitor of gap-junction. Our overall results showed that bystander cell-killing effect was observed in the cells with wild-type P53, but not in the P53-mutated cells. There is clear evidence that the spot scanning irradiation system of carbon ions enables the enhanced cell killing in cells with wild-type P53 gene via gap-junction mediated bystander effect.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "15th International Congress of Radiation Research", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "鈴木, 雅雄"}], "nameIdentifiers": [{"nameIdentifier": "705145", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舟山, 知夫"}], "nameIdentifiers": [{"nameIdentifier": "705146", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "横田, 裕一郎"}], "nameIdentifiers": [{"nameIdentifier": "705147", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 芳代"}], "nameIdentifiers": [{"nameIdentifier": "705148", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池田, 裕子"}], "nameIdentifiers": [{"nameIdentifier": "705149", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂下, 哲哉"}], "nameIdentifiers": [{"nameIdentifier": "705150", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林, 泰彦"}], "nameIdentifiers": [{"nameIdentifier": "705151", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上, 健"}], "nameIdentifiers": [{"nameIdentifier": "705152", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 雅雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "705153", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村上 健", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "705154", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the spot scanning system with pencil beams ", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the spot scanning system with pencil beams "}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/71665", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-05-30"}, "publish_date": "2015-05-30", "publish_status": "0", "recid": "71665", "relation": {}, "relation_version_is_last": true, "title": ["P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the spot scanning system with pencil beams "], "weko_shared_id": -1}
P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the spot scanning system with pencil beams
https://repo.qst.go.jp/records/71665
https://repo.qst.go.jp/records/71665fa6e3019-1944-4843-a193-39bd960fe9e0
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-05-30 | |||||
タイトル | ||||||
タイトル | P53-dependent cell-killing effect via bystander effect using carbon-ion microbeams simulating the spot scanning system with pencil beams | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
鈴木, 雅雄
× 鈴木, 雅雄× 舟山, 知夫× 横田, 裕一郎× 鈴木, 芳代× 池田, 裕子× 坂下, 哲哉× 小林, 泰彦× 村上, 健× 鈴木 雅雄× 村上 健 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Since 1994, a Phase I/II clinical study and radiotherapy have been carrying out using carbon-ion beams generated with the Heavy Ion Medical Accelerator in Chiba (HIMAC) at National Institute of Radiological Sciences. Now we constructed the new treatment facility for the advanced carbon-ion therapy applying a 3D fast spot scanning system with pencil beams. To identify the biological effects of a spot scanning carbon-ion beams in vitro, we demonstrated cell-killing effect of human tumor cell lines using the spot scanning irradiation of carbon-ion microbeams generated with the Takasaki Ion Accelerators for Advanced Radiation Application (TIARA) in Japan Atomic Energy Agency. We irradiated either 4-cell lines with wild-type P53 or 4-cell lines with mutated-type P53 using the TIARA microbeams collimated by 20µm in diameter. We can easily estimate the number of the directly irradiated cells to be 0.01% level of the total cells on the dish using the highly controlled microbeam irradiation system. The percent survival in the cells with wild-type P53 was around 90%, while almost 100% was observed in the cells with mutated-type P53. We can expect the percent survival of 99.99% level when the cell-killing effect was induced in directly irradiated 0.01% cells, assuming no bystander effect. However, the percent in the cells with wild-type P53 was significantly low beyond our expectation. Moreover, the percent returned to 100% when using a specific inhibitor of gap-junction mediated cell-cell communication. The results are consistent with the data using the carbon-ion broad beams with the shielding method at HIMAC, which irradiation was carried out using 4 different protocols; (1) All cells were irradiated; (2) Irradiated and unirradiated cells were pooled in a 1:1 ratio as a single culture; (3) Half of cells were irradiated using beam stopper; and (4) Half of cells were irradiated with a specific inhibitor of gap-junction. Our overall results showed that bystander cell-killing effect was observed in the cells with wild-type P53, but not in the P53-mutated cells. There is clear evidence that the spot scanning irradiation system of carbon ions enables the enhanced cell killing in cells with wild-type P53 gene via gap-junction mediated bystander effect. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 15th International Congress of Radiation Research | |||||
発表年月日 | ||||||