{"_buckets": {"deposit": "91d127d2-cdd6-4882-99ec-8e5555554211"}, "_deposit": {"created_by": 1, "id": "71445", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "71445"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00071445", "sets": ["28"]}, "author_link": ["702445", "702442", "702441", "702440", "702443", "702439", "702444"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2014-05-23", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "【背景・目的】薬剤送達システム(Drug Delivery System, DDS)の発展に伴い,リポソーム,高分子ミセル,デンドリマーなど様々なナノ粒子が開発されている.我々はこれまでに,MR造影剤,蛍光色素,および抗がん剤を内包し,熱を加えることにより効果的に薬剤を表出させるマルチモーダル温度応答性リポソーム(Multimodal Thermo-sensitive Polymer-modified Liposome, MTPL)を作成し,その腫瘍集積性,加温によるMTPL崩壊の可視化,および治療効果について検討した.本発表では,放射線治療の一種である重粒子線治療とナノDDS治療を併用した”ナノDDS・重粒子線治療”の実現に向け,重粒子線(炭素線)照射後のMTPLの腫瘍集積性,局所加温によるMTPL崩壊の評価,および治療効果について検討を行った.\n【方法】実験には,マウス由来大腸癌Colon26細胞(1.0 106 cells / 50 l)をBALB/cヌードマウス(日本SLC)臀部の左右2か所の皮下に移植した担がんモデルマウスを使用した.炭素線は片側の腫瘍のみに対し照射(5 Gy)し,その直後に硫酸マンガン,ローダミン,ならびにドキソルビシンを含有したMTPL(200 l)を尾静脈から投与した.局所加温は,MTPL投与後2~3時間後に自作の温水環流装置を用い,腫瘍内に挿入した温度プローブの測定値で42.5℃,10分間加温した.MTPLの腫瘍集積性ならびに崩壊の可視化は,前臨床用7.0テスラMR装置(Kobelco, Jastec, Bruker-biospin)を使用し,炭素線照射12時間,3日および7日後に取得したT1強調画像ならびにT1定量値を用いて評価した.治療効果は,炭素線照射+MTPL投与+局所加温群と,設定した対照群(炭素線照射のみ群,炭素線照射+MTPL群,炭素線照射+局所加温群)の腫瘍サイズを経時的に計測し検討した.\n【結果・考察】炭素線照射+MTPL投与群において腫瘍集積性を検討したところ,照射12時間後の照射側と非照射側の腫瘍内T1値に差はなかった.また,炭素線照射+MTPL投与+局所加温群においては治療側の腫瘍内T1値が非治療側の腫瘍内T1値より短縮したことが認められた.これらのことから,今回の照射線量においては,MTPLの腫瘍集積性が低下しないことが確認でき,加温後のMTPLの崩壊が可視化できた.治療効果に関しては,照射8日後までの腫瘍サイズを比較したところ,炭素線照射+MTPL投与+局所加温群は,全ての対照群に比べ有意にその増大速度が低下した.このことから,ナノDDS・重粒子線治療の併用は,それぞれの治療を阻害することなく,抗腫瘍効果を増大できると考えられた.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第9回日本分子イメージング学会・学術集会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "國領, 大介"}], "nameIdentifiers": [{"nameIdentifier": "702439", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青木, 伊知男"}], "nameIdentifiers": [{"nameIdentifier": "702440", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河野, 健司"}], "nameIdentifiers": [{"nameIdentifier": "702441", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀, 恒夫"}], "nameIdentifiers": [{"nameIdentifier": "702442", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "國領 大介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "702443", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "青木 伊知男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "702444", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐賀 恒夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "702445", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "炭素線照射後の温度応答性リポソームの腫瘍集積性と治療効果の評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "炭素線照射後の温度応答性リポソームの腫瘍集積性と治療効果の評価"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/71445", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-05-22"}, "publish_date": "2014-05-22", "publish_status": "0", "recid": "71445", "relation": {}, "relation_version_is_last": true, "title": ["炭素線照射後の温度応答性リポソームの腫瘍集積性と治療効果の評価"], "weko_shared_id": -1}
炭素線照射後の温度応答性リポソームの腫瘍集積性と治療効果の評価
https://repo.qst.go.jp/records/71445
https://repo.qst.go.jp/records/7144584acea4b-d44c-49bf-b5f2-5d6d578c658a
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-05-22 | |||||
タイトル | ||||||
タイトル | 炭素線照射後の温度応答性リポソームの腫瘍集積性と治療効果の評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
國領, 大介
× 國領, 大介× 青木, 伊知男× 河野, 健司× 佐賀, 恒夫× 國領 大介× 青木 伊知男× 佐賀 恒夫 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 【背景・目的】薬剤送達システム(Drug Delivery System, DDS)の発展に伴い,リポソーム,高分子ミセル,デンドリマーなど様々なナノ粒子が開発されている.我々はこれまでに,MR造影剤,蛍光色素,および抗がん剤を内包し,熱を加えることにより効果的に薬剤を表出させるマルチモーダル温度応答性リポソーム(Multimodal Thermo-sensitive Polymer-modified Liposome, MTPL)を作成し,その腫瘍集積性,加温によるMTPL崩壊の可視化,および治療効果について検討した.本発表では,放射線治療の一種である重粒子線治療とナノDDS治療を併用した”ナノDDS・重粒子線治療”の実現に向け,重粒子線(炭素線)照射後のMTPLの腫瘍集積性,局所加温によるMTPL崩壊の評価,および治療効果について検討を行った. 【方法】実験には,マウス由来大腸癌Colon26細胞(1.0 106 cells / 50 l)をBALB/cヌードマウス(日本SLC)臀部の左右2か所の皮下に移植した担がんモデルマウスを使用した.炭素線は片側の腫瘍のみに対し照射(5 Gy)し,その直後に硫酸マンガン,ローダミン,ならびにドキソルビシンを含有したMTPL(200 l)を尾静脈から投与した.局所加温は,MTPL投与後2~3時間後に自作の温水環流装置を用い,腫瘍内に挿入した温度プローブの測定値で42.5℃,10分間加温した.MTPLの腫瘍集積性ならびに崩壊の可視化は,前臨床用7.0テスラMR装置(Kobelco, Jastec, Bruker-biospin)を使用し,炭素線照射12時間,3日および7日後に取得したT1強調画像ならびにT1定量値を用いて評価した.治療効果は,炭素線照射+MTPL投与+局所加温群と,設定した対照群(炭素線照射のみ群,炭素線照射+MTPL群,炭素線照射+局所加温群)の腫瘍サイズを経時的に計測し検討した. 【結果・考察】炭素線照射+MTPL投与群において腫瘍集積性を検討したところ,照射12時間後の照射側と非照射側の腫瘍内T1値に差はなかった.また,炭素線照射+MTPL投与+局所加温群においては治療側の腫瘍内T1値が非治療側の腫瘍内T1値より短縮したことが認められた.これらのことから,今回の照射線量においては,MTPLの腫瘍集積性が低下しないことが確認でき,加温後のMTPLの崩壊が可視化できた.治療効果に関しては,照射8日後までの腫瘍サイズを比較したところ,炭素線照射+MTPL投与+局所加温群は,全ての対照群に比べ有意にその増大速度が低下した.このことから,ナノDDS・重粒子線治療の併用は,それぞれの治療を阻害することなく,抗腫瘍効果を増大できると考えられた. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第9回日本分子イメージング学会・学術集会 | |||||
発表年月日 | ||||||
日付 | 2014-05-23 | |||||
日付タイプ | Issued |