{"_buckets": {"deposit": "c0eac47b-f59f-4877-a3d8-12a36a77b337"}, "_deposit": {"created_by": 1, "id": "69849", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "69849"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00069849", "sets": ["28"]}, "author_link": ["685769", "685770", "685768"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2009-09-12", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A dose audit using a photoluminescent glass dosimeter was conducted in radiation therapy facilities in a number of East-Asian countries. The audit was performed for the reference condition of linac X-ray beams, which was a 10x10 cm2 field and a 10cm depth with a SSD of 90 cm. Eight facilities from 5 countries, China, Korea, Indonesia, Viet Nam and the Philippines, participated in this audit. The ratios of deviation between the user-stated dose and the NIRS measured dose were analyzed. Among 24 X-rays beams measured from 6 to 20MV, 22 beams were within optimum levels (\u0026#61617;3%) and 1 beam was out of the optimum level but within the tolerance level (\u0026#61617;5%). However, 1 beam exceeded the tolerance level. The standard deviation of the ratios of deviation was 1.4%. A thorough and lengthy investigation was performed regarding this beam, which was observed to have a large rate of deviation (+6.1%). Finally, the cause became clear when it was deter-mined that an incorrect pressure value in the calibration of a monitoring unit had been used. This event shows the impor-tance of external audit in radiation therapy.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "WORLD CONGRESS 2009", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mizuno, Hideyuki"}], "nameIdentifiers": [{"nameIdentifier": "685768", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "685769", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "水野 秀之", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "685770", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/69849", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-09-15"}, "publish_date": "2009-09-15", "publish_status": "0", "recid": "69849", "relation": {}, "relation_version_is_last": true, "title": ["Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries"], "weko_shared_id": -1}
Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries
https://repo.qst.go.jp/records/69849
https://repo.qst.go.jp/records/698490ed4b335-0ba0-4160-81ba-99182aa8cd2f
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-09-15 | |||||
タイトル | ||||||
タイトル | Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Mizuno, Hideyuki
× Mizuno, Hideyuki× et.al× 水野 秀之 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A dose audit using a photoluminescent glass dosimeter was conducted in radiation therapy facilities in a number of East-Asian countries. The audit was performed for the reference condition of linac X-ray beams, which was a 10x10 cm2 field and a 10cm depth with a SSD of 90 cm. Eight facilities from 5 countries, China, Korea, Indonesia, Viet Nam and the Philippines, participated in this audit. The ratios of deviation between the user-stated dose and the NIRS measured dose were analyzed. Among 24 X-rays beams measured from 6 to 20MV, 22 beams were within optimum levels (3%) and 1 beam was out of the optimum level but within the tolerance level (5%). However, 1 beam exceeded the tolerance level. The standard deviation of the ratios of deviation was 1.4%. A thorough and lengthy investigation was performed regarding this beam, which was observed to have a large rate of deviation (+6.1%). Finally, the cause became clear when it was deter-mined that an incorrect pressure value in the calibration of a monitoring unit had been used. This event shows the impor-tance of external audit in radiation therapy. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | WORLD CONGRESS 2009 | |||||
発表年月日 | ||||||
日付 | 2009-09-12 | |||||
日付タイプ | Issued |