WEKO3
アイテム
{"_buckets": {"deposit": "033fe789-afe0-4017-b79d-d65900a5faef"}, "_deposit": {"created_by": 1, "id": "69819", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "69819"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00069819", "sets": ["28"]}, "author_link": ["685525", "685526", "685524", "685527", "685528", "685523", "685529", "685530"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2009-07-30", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To develop an algorithm to resolve intrinsic problems with dose calculations using pencil beams when particles involved in each beam are overreaching a lateral density interface or when they are detouring in a laterally heterogeneous medium. Method and Materials: A finding on a Gaussian distribution, such that it can be approximately decomposed into multiple narrower, shifted, and scaled ones, was applied to dynamic splitting of pencil beams implemented in a dose calculation algorithm for proton and ion beams. The method was tested in an experiment with a range-compensated carbon-ion beam. Its effectiveness and efficiency were evaluated for carbon-ion and proton beams in a heterogeneous phantom model. Results: The splitting dose calculation reproduced the detour effect observed in the experiment, which amounted to about 10% at a maximum or as large as the lateral particle-disequilibrium effect. The proton-beam dose generally showed large scattering effects including the overreach and detour effects. The overall computational times were 9 s and 45 s for non-splitting and splitting carbon-ion beams and 15 s and 66 s for non-splitting and splitting proton beams. Conclusions: The beam-splitting method was developed and verified to resolve the intrinsic size limitation of the Gaussian pencil-beam model in dose calculation algorithms. The computational speed slowed down by factor of 5, which would be tolerable for dose accuracy improvement at a maximum of 10%, in our test case.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "AAPM Annual Meeting 2009", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kanematsu, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "685523", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Komori, Masataka"}], "nameIdentifiers": [{"nameIdentifier": "685524", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yonai, Shunsuke"}], "nameIdentifiers": [{"nameIdentifier": "685525", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishizaki, Azusa"}], "nameIdentifiers": [{"nameIdentifier": "685526", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "兼松 伸幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "685527", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小森 雅孝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "685528", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "米内 俊祐", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "685529", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石崎 梓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "685530", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/69819", "pubdate": {"attribute_name": "公開日", "attribute_value": "2009-08-02"}, "publish_date": "2009-08-02", "publish_status": "0", "recid": "69819", "relation": {}, "relation_version_is_last": true, "title": ["Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles"], "weko_shared_id": -1}
Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles
https://repo.qst.go.jp/records/69819
https://repo.qst.go.jp/records/69819d4248a3c-fb73-43e0-8b11-a44ffa6ac558
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-08-02 | |||||
タイトル | ||||||
タイトル | Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kanematsu, Nobuyuki
× Kanematsu, Nobuyuki× Komori, Masataka× Yonai, Shunsuke× Ishizaki, Azusa× 兼松 伸幸× 小森 雅孝× 米内 俊祐× 石崎 梓 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To develop an algorithm to resolve intrinsic problems with dose calculations using pencil beams when particles involved in each beam are overreaching a lateral density interface or when they are detouring in a laterally heterogeneous medium. Method and Materials: A finding on a Gaussian distribution, such that it can be approximately decomposed into multiple narrower, shifted, and scaled ones, was applied to dynamic splitting of pencil beams implemented in a dose calculation algorithm for proton and ion beams. The method was tested in an experiment with a range-compensated carbon-ion beam. Its effectiveness and efficiency were evaluated for carbon-ion and proton beams in a heterogeneous phantom model. Results: The splitting dose calculation reproduced the detour effect observed in the experiment, which amounted to about 10% at a maximum or as large as the lateral particle-disequilibrium effect. The proton-beam dose generally showed large scattering effects including the overreach and detour effects. The overall computational times were 9 s and 45 s for non-splitting and splitting carbon-ion beams and 15 s and 66 s for non-splitting and splitting proton beams. Conclusions: The beam-splitting method was developed and verified to resolve the intrinsic size limitation of the Gaussian pencil-beam model in dose calculation algorithms. The computational speed slowed down by factor of 5, which would be tolerable for dose accuracy improvement at a maximum of 10%, in our test case. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | AAPM Annual Meeting 2009 | |||||
発表年月日 | ||||||
日付 | 2009-07-30 | |||||
日付タイプ | Issued |