ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Tumor metastasis exposed to high-LET radiations

https://repo.qst.go.jp/records/64014
https://repo.qst.go.jp/records/64014
3eb1a02e-b15b-4d17-bb6e-7feaca646695
Item type 会議発表用資料 / Presentation(1)
公開日 2010-09-22
タイトル
タイトル Tumor metastasis exposed to high-LET radiations
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 631539

Matsumoto, Yoshitaka

Search repository
Uzawa, Akiko

× Uzawa, Akiko

WEKO 631540

Uzawa, Akiko

Search repository
Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 631541

Hirayama, Ryoichi

Search repository
Koike, Sachiko

× Koike, Sachiko

WEKO 631542

Koike, Sachiko

Search repository
Okayasu, Ryuichi

× Okayasu, Ryuichi

WEKO 631543

Okayasu, Ryuichi

Search repository
Ando, Koichi

× Ando, Koichi

WEKO 631544

Ando, Koichi

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 631545

Furusawa, Yoshiya

Search repository
et.al

× et.al

WEKO 631546

et.al

Search repository
松本 孔貴

× 松本 孔貴

WEKO 631547

en 松本 孔貴

Search repository
鵜澤 玲子

× 鵜澤 玲子

WEKO 631548

en 鵜澤 玲子

Search repository
平山 亮一

× 平山 亮一

WEKO 631549

en 平山 亮一

Search repository
小池 幸子

× 小池 幸子

WEKO 631550

en 小池 幸子

Search repository
岡安 隆一

× 岡安 隆一

WEKO 631551

en 岡安 隆一

Search repository
古澤 佳也

× 古澤 佳也

WEKO 631552

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: The aim of this study is to clarify the effect of carbon ion beams (C-ion) on metastatic potential of melanoma in vitro and in vivo.
Materials and Methods: A highly metastatic mouse malignant melanoma cell line B16/BL6 were maintained in RPMI-1640 medium supplemented with 10% FBS and antibiotics. [in vitro] Samples were prepared 2 days before and then irradiated with C-ions or X-rays. Surviving fractions were obtained using colony formation assay. Migration and invasion activity as metastatic potentials of the cells were examined using the Boyden-chamber method and the Matrigel invasion assay. [in vivo] The cells were implanted in right-leg of C57BL/6J mice at 1x106 cells/mouse 9-10 days before irradiation. Tumors were irradiated at the center of 6cm-SOBP of C-ions, or gamma-rays. Radiosensitivity for whole tumor was obtained by the tumor growth delay method, and that for individual cell in a tumor was obtained by an in vivo-in vitro assay. The metastatic effects were analyzed with the spontaneous lung metastasis model. The dose averaged LET values of carbon beams were approximately 50 keV/um.
Results: [in vitro] Survival curves showed higher cytotoxic effects of C-ions compared with X-rays, and the RBE values were 1.96. The potential of migration and invasion were suppressed by C-ions at all dose points (0.50 to 8.0 Gy) tested, however it was enhanced by X-rays at low dose points (0.50 and 1.0 Gy) than non-irradiated controls. The RBE values obtained from migration and invasion test were higher than that from cell killing. [in vivo] C-ions significantly suppressed the tumor growth, and the RBE was 2.64. The numbers of lung metastatic nodules after tumor-irradiations decreased with the dose, and C-ions were more effective compared with gamma-rays. The metastatic potentials of survived cells in a tumor after irradiation was analyzed with the number of metastatic lung colony from implanted tumors and survival of irradiated and explanted cells from a tumor. Smaller number of metastasis was found for C-ions than gamma-rays when the numbers were compared with biological equivalent dose.
Conclusion: It might suggest that C-ion inhibit metastasis at radiotherapy compared with low-LET photons.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NIRS-KI Joint Symposium on Carbon Ion Therapy
発表年月日
日付 2010-09-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:16:24.435082
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3