WEKO3
アイテム
{"_buckets": {"deposit": "9996278c-8813-4734-9f35-878a05b36dc1"}, "_deposit": {"created_by": 1, "id": "62605", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "62605"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00062605", "sets": ["29"]}, "author_link": ["618520", "618521", "618514", "618511", "618509", "618512", "618517", "618518", "618522", "618508", "618519", "618510", "618513", "618516", "618523", "618515"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2008-04-06", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose\n直腸癌局所再発に関して、IMRTを用いてSUV1.5以上の領域(biological target volume; BTV)にfocal dose-escalationが可能であるかpreclinicalに検討した。\n\\nMaterials and Methods\n8症例で、GTV+5mm=CTV, CTV or BTV+5mm=PTVとして、PTV-PET\u003e66Gy/30fr, \nPTV-CT\u003e60Gy/30fr, critical organ \u003c60Gy/30frとなるようにinverse planningを施行。conventional RT 60Gy/30frとの比較を行った。\n\\nResults\ncritical organに対して、V50Gy-CRT vs V50Gy-IMRT; 11.3±3.2% vs 5.9±3.0%、V60Gy-CRT\nvs V60Gy-IMRT; 1.5±1.3% vs 1.4±1.1%、 Dmean-CRT vs Dmean-IMRT; 23.3±6.2 Gy vs 18.1±4.5 Gy (p=0.006, p=0.87, p=0.08, respectively; T検定)となった。\n\\n以上からBTV+5mmにIMRTで66Gy/30fr処方しても、CRTによる60Gy/30frと比較して、pelvic\norganのV50Gyを有意に減量することが可能であり、かつV60GyおよびDmeanに有意差はなかった。\n\\nConclusions\nIMRTを用いたBTVに対する10%(6Gy)のfocal dose-escalation は、critical organの合併症のriskを増やすことなく可能である。", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第67回日本医学放射線学会総会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "神宮, 啓一"}], "nameIdentifiers": [{"nameIdentifier": "618508", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金田, 朋洋"}], "nameIdentifiers": [{"nameIdentifier": "618509", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武田, 賢"}], "nameIdentifiers": [{"nameIdentifier": "618510", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "奈良崎, 覚太朗"}], "nameIdentifiers": [{"nameIdentifier": "618511", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "目時, 隆博"}], "nameIdentifiers": [{"nameIdentifier": "618512", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川, 芳弘"}], "nameIdentifiers": [{"nameIdentifier": "618513", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "有賀, 久哲"}], "nameIdentifiers": [{"nameIdentifier": "618514", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤本, 圭介"}], "nameIdentifiers": [{"nameIdentifier": "618515", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高井, 良尋"}], "nameIdentifiers": [{"nameIdentifier": "618516", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田, 章吾"}], "nameIdentifiers": [{"nameIdentifier": "618517", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "神宮 啓一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "618518", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武田 賢", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "618519", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小川 芳弘", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "618520", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "有賀 久哲", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "618521", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高井 良尋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "618522", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 章吾", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "618523", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "PET guided IMRTに関する初期研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "PET guided IMRTに関する初期研究"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/62605", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-06-30"}, "publish_date": "2008-06-30", "publish_status": "0", "recid": "62605", "relation": {}, "relation_version_is_last": true, "title": ["PET guided IMRTに関する初期研究"], "weko_shared_id": -1}
PET guided IMRTに関する初期研究
https://repo.qst.go.jp/records/62605
https://repo.qst.go.jp/records/62605e6539d09-40ff-46e8-91fe-287b3ee4ef5a
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-06-30 | |||||
タイトル | ||||||
タイトル | PET guided IMRTに関する初期研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
神宮, 啓一
× 神宮, 啓一× 金田, 朋洋× 武田, 賢× 奈良崎, 覚太朗× 目時, 隆博× 小川, 芳弘× 有賀, 久哲× 藤本, 圭介× 高井, 良尋× 山田, 章吾× 神宮 啓一× 武田 賢× 小川 芳弘× 有賀 久哲× 高井 良尋× 山田 章吾 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose 直腸癌局所再発に関して、IMRTを用いてSUV1.5以上の領域(biological target volume; BTV)にfocal dose-escalationが可能であるかpreclinicalに検討した。 \nMaterials and Methods 8症例で、GTV+5mm=CTV, CTV or BTV+5mm=PTVとして、PTV-PET>66Gy/30fr, PTV-CT>60Gy/30fr, critical organ <60Gy/30frとなるようにinverse planningを施行。conventional RT 60Gy/30frとの比較を行った。 \nResults critical organに対して、V50Gy-CRT vs V50Gy-IMRT; 11.3±3.2% vs 5.9±3.0%、V60Gy-CRT vs V60Gy-IMRT; 1.5±1.3% vs 1.4±1.1%、 Dmean-CRT vs Dmean-IMRT; 23.3±6.2 Gy vs 18.1±4.5 Gy (p=0.006, p=0.87, p=0.08, respectively; T検定)となった。 \n以上からBTV+5mmにIMRTで66Gy/30fr処方しても、CRTによる60Gy/30frと比較して、pelvic organのV50Gyを有意に減量することが可能であり、かつV60GyおよびDmeanに有意差はなかった。 \nConclusions IMRTを用いたBTVに対する10%(6Gy)のfocal dose-escalation は、critical organの合併症のriskを増やすことなく可能である。 |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第67回日本医学放射線学会総会 | |||||
発表年月日 | ||||||
日付 | 2008-04-06 | |||||
日付タイプ | Issued |